E-Stop & Guard Monitoring Safety Relays

ES Series and GM Series

Safety Relay Module
  • Modules monitor up to 10 external devices for contact failure or wiring faults
  • Module goes into lockout mode if it detects a fault
  • Available voltages include 24V dc 24V ac/dc 115V ac or 12 to 24V dc or 230V ac or 12 to 24V ac/dc
  • Modules monitor positive-opening E-stop and interlock switches
  • Models are available with 2 to 4 normally open safety outputs, depending on module
  • Safety outputs are rated 4 or 6 amps, depending on module
  • Non-safety auxiliary outputs are available on most modules
  • Two modules allow central monitoring and control over a DeviceNet control network
  • Ratings are NEMA 1 and at least IEC IP20
  • Housings are rugged polycarbonate
  • Bright red and green LED indicators show modules operating status

Technical Literature

Date
Type
Size
GM-FA-10J Gate Monitoring Module (24 VAC/VDC, Single or Dual Inputs)
13 Jan 2025
Datasheet
454K
ES-FA-9AA and ES-FA-11AA Safety Modules (Short Multi-Lingual)
20 Jan 2022
Datasheet
92K
ES-UA/VA-5A Safety Modules (4 N.O. safety outputs, 12-24 V DC/115  or 230 V AC)
11 Aug 2021
Datasheet
466K
ES-FA-6G Safety Module (3 N.O. safety outputs, 24V ac/dc, 1 input)
12 Jul 2019
Datasheet
296K
ES-TA-3F1 Safety Module (2 N.O. safety outputs, 24V dc, 10 inputs, DeviceNet)
18 Aug 2006
Datasheet
651K
ES-FA-9A Safety Module (3 N.O. safety outputs, 24V ac/dc, 1 or 2 inputs)
15 Mar 2004
Datasheet
126K
ES-TA-3D1 Safety Module (2 N.O. safety outputs, 24V dc, 6 inputs, DeviceNet)
10 Nov 2003
Datasheet
456K
Date
Type
Size
Date
Type
Size
ES-UA/VA-5A Safety Modules (4 N.O. safety outputs, 12-24 V DC/115  or 230 V AC) (German)
09/01/22
Datasheet
470K
Date
Type
Size
Date
Type
Size
ES-TN-1Hx Safety Modules (4 N.O. safety outputs, fixed delay)  - Japanese
04/28/11
Datasheet
683K
ES-UA-5A/ES-VA-5A Safey Modules - Japanese
04/28/11
Datasheet
613K
ES-TN-1H5/6 Safety Modules (4 N.O. safety ouptus, 24V dc, adj delay) - Japanese
04/28/11
Datasheet
728K
ES-FA-6G Safety Module (3 N.O. safety outputs, 24Vac/dc, 1 input) - Japanese
04/28/11
Datasheet
298K
ES-FA-9AA Safety Module (3 N.O safety outputs,24Vac/dc,1 or 2 inputs) - Japanese
04/28/11
Datasheet
475K
ES-GA-5A/ES-HA-5A Safety Modules - Japanese
04/28/11
Datasheet
285K
ES-TN-14H5/6 Safety Modules (8 N.O safety outputs, 24Vdc, adj delay) - Japanese
04/28/11
Datasheet
590K
Date
Type
Size
ES-FA-9AA and ES-FA-11AA Safety Modules (Spanish)
05/17/24
Product Manual
2.6MB

Software

Date
Type
Size
ES-TA-3F1
ES-TA-3F1
13 Jan 2003
Software
3K
ES-TA-3D1
ES-TA-3D1
13 Jan 2003
Software
3K
Icon 131, bmp format
13 Jan 2003
Software
1K
Icon 131, ico format
13 Jan 2003
Software
1K

Marketing Literature

Date
Type
Size
Safety Solutions Catalog
Safety Solutions Catalog
2 Dec 2024
Product Brochure
11.5MB
Safety Overview Flyer
Safety Overview Flyer
15 Feb 2023
Product Brochure
2.5MB
(Part D) 2006-07 Safety Catalog (Pg 105-134) - Safety Modules
4 Apr 2006
Catalog
1.9MB
Date
Type
Size
CN_Safety Solutions Catalog
安全解决方案
06/09/23
Product Brochure
14.8MB
Date
Type
Size
Machine Safety Catalog (09) - Emergency Stop Safety Modules - Japanese
11/18/02
Catalog
814K
Date
Type
Size
F142 Safety Solutions Brochure
01/06/21
Product Brochure
16.4MB
Gate Monitoring Module
Gate Monitoring Module

The safety module monitors the magnetic sensor for actuation when the guard opens, for failure modes, and for closing. It also provides two safe switching outputs and monitoring of device under control.

Read More

Product Selection

Loading...

Narrow Results

clear all filters

Number of Safe Inputs

  • (5)
  • (1)

Output Configuration

  • (2)
  • (2)
  • (2)

Supply Voltage

  • (3)
  • (1)
  • (1)
  • (1)

Gate Switch (NC/NC) Input

  • (2)
  • (4)

Gate Switch (NC/NO) Input

  • (5)
  • (1)

Safety Module Type

  • (5)
  • (1)
View All View Less
selected filters
  1. ES-FA-9AA

    logo with r symbol

    Safety Relay Module for E-Stop/Rope Pull/Interlock
    Supply Voltage: 24 V ac/dc
    Safety Input: 1 Dual/Single Channel
    Safety Output: 3 NO, 6 A; Aux Output: None
    Terminal Block: Removable; Width: 22.5 mm
    Self-Checking Circuitry, Auto/Manual Reset

  2. ES-UA-5A

    logo with r symbol

    Safety Relay Module for E-Stop/Rope Pull/Interlock
    Supply Voltage: 115 V ac or 12-24 V dc
    Safety Input: 1 Dual/Single Channel
    Safety Output: 4 NO, 6 A; Aux Output: 1 NC, 5 A and 2 Solid-State 0.1 A
    Terminal Block: Removable; Width: 45 mm
    Self-Checking Circuitry, Auto/Manual Reset

  3. ES-FA-11AA

    logo with r symbol

    Safety Relay Module for E-Stop/Rope Pull/Interlock
    Supply Voltage: 24 V ac/dc
    Safety Input: 1 Dual/Single Channel
    Safety Output: 2 NO, 7 A; Aux Output: 1 NC, 7 A
    Terminal Block: Removable; Width: 22.5 mm
    Self-Checking Circuitry, Auto/Manual Reset

  4. GM-FA-10J

    logo with r symbol

    Safety Relay Module for Interlocks
    Supply Voltage: 24 V ac/dc
    Safety Input: Interlocks with complementary contacts
    Safety Output: 2 NO, 6 A; Aux Output: None
    Terminal Block: Removable; Width: 22.5 mm
    Self-Checking Circuitry, Auto/Manual Reset

  5. ES-FA-6G

    logo with r symbol

    Safety Relay Module for E-Stop/Rope Pull/Interlock
    Supply Voltage: 24 V ac/dc
    Safety Input: 1 Single Channel
    Safety Output: 3 NO, 6 A; Aux Output: 1 NC, 6 A
    Terminal Block: Fixed; Width: 22.5 mm
    Self-Checking Circuitry, Auto/Manual Reset

  6. ES-VA-5A

    logo with r symbol

    Safety Relay Module for E-Stop/Rope Pull/Interlock
    Supply Voltage: 230 V ac or 12-24 V dc
    Safety Input: 1 Dual/Single Channel
    Safety Output: 4 NO, 6 A; Aux Output: 1 NC, 5 A and 2 Solid-State 0.1 A