• Back

  • SGS Series Mute Arm Kits

    SGS 3 Grid Options

    SGS Series Muting Arm Kits make it easy to add muting capabilities to any application requiring body detection. The mute arm kits combine pre-mounted hardware with Q20 retroreflective sensors and retroreflective target reflectors. They are designed to be used with SGS Safety Grid System models featuring Integral Muting.

    • Pre-assembled for plug-and-play connection to the SGS grid
    • Available in four different configurations to solve a wide range of applications
    • Uses Q20 retroreflective sensors specifically designed for SGS Safety Grid Systems
    • Adjusts easily to support line changes
    • Wiring connection block and cable accessories are available

    Technical Literature

    Date
    Type
    Size
    SGS Safety Grid System (Emitter-Receiver Models) Instruction Manual
    5 Oct 2023
    Product Manual
    7.7MB
    SGS Safety Grid System (Active-Passive Models) Instruction Manual
    5 Oct 2023
    Product Manual
    8.1MB
    SGS Safety Grid System (Emitter-Receiver Models with Integral Muting) Instruction Manual
    5 Oct 2023
    Product Manual
    7.5MB
    SGS Safety Grid System (Active-Passive Models with Integral Muting) Instruction Manual
    5 Oct 2023
    Product Manual
    7.9MB
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting
    2 Aug 2021
    Datasheet
    633K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models)
    16 Jan 2018
    Checkout Procedure
    92K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models)
    16 Jan 2018
    Checkout Procedure
    121K
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models)
    16 Jan 2018
    Checkout Procedure
    121K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models)
    16 Jan 2018
    Checkout Procedure
    88K
    SGSA-MCB Safety Grid System Connection Box
    22 Sep 2017
    Datasheet
    460K
    Date
    Type
    Size
    SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (French)
    12/19/19
    Product Manual
    13.6MB
    SGS Safety Grid System (Emitter/Receiver) -- Instruction Manual (French)
    12/19/19
    Product Manual
    4.6MB
    SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (French)
    12/19/19
    Product Manual
    14.5MB
    SGS Safety Grid System (ActivePassive) -- Instruction Manual (French)
    12/19/19
    Product Manual
    5.4MB
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (French)
    01/04/19
    Checkout Procedure
    82K
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (French)
    01/04/19
    Checkout Procedure
    115K
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (French)
    08/06/18
    Datasheet
    583K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models) (French)
    08/06/18
    Checkout Procedure
    115K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (French)
    08/06/18
    Checkout Procedure
    86K
    Date
    Type
    Size
    SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (German)
    02/14/20
    Product Manual
    13.3MB
    SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (German)
    02/14/20
    Product Manual
    14.5MB
    SGS Safety Grid System (ActivePassive) -- Instruction Manual (German)
    02/14/20
    Product Manual
    5.4MB
    SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (German)
    02/14/20
    Product Manual
    4.6MB
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (German)
    01/04/19
    Checkout Procedure
    108K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (German)
    01/04/19
    Checkout Procedure
    75K
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (German)
    08/06/18
    Datasheet
    582K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models) (German)
    SGS Sicherheitsgittersystem
    08/06/18
    Checkout Procedure
    108K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (German)
    SGS Sicherheitsgittersystem
    08/06/18
    Checkout Procedure
    78K
    Date
    Type
    Size
    SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (Italian)
    02/14/20
    Product Manual
    13.3MB
    SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (Italian)
    02/14/20
    Product Manual
    14.5MB
    SGS Safety Grid System (ActivePassive) -- Instruction Manual (Italian)
    02/14/20
    Product Manual
    5.4MB
    SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (Italian)
    02/14/20
    Product Manual
    4.6MB
    SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (Italian)
    01/04/19
    Checkout Procedure
    114K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (Italian)
    01/04/19
    Checkout Procedure
    82K
    SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (Italian)
    08/06/18
    Datasheet
    581K
    SGS Safety Grid System Daily Checkout Procedure (Muting Models) (Italian)
    08/06/18
    Checkout Procedure
    115K
    SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (Italian)
    08/06/18
    Checkout Procedure
    83K

    Marketing Literature

    Date
    Type
    Size
    Safety Solutions Catalog
    Safety Solutions Catalog
    2 Dec 2024
    Product Brochure
    11.5MB
    Date
    Type
    Size
    CN_Safety Solutions Catalog
    安全解决方案
    06/09/23
    Product Brochure
    14.8MB

    Question:     How do I choose between the configuration options?

    Answer: The chart below provides recommended mute arm kit configurations for box or pallet muting:

    Product Selection

    Loading...

    Narrow Results

    clear all filters

    Configuration

    • (1)
    • (1)
    • (1)
    • (1)
    View All View Less
    selected filters
    1. SGSA-ML-R-LPQ20

      logo with r symbol

      Safety Grid System and LS Light Curtain, Accessory
      Mute Arm Kit: L Configuration Right Side
      Includes: One Sensor Arm with Two Q20PLPQ5 Sensors Installed
      One Reflector Arm with Two Reflectors Installed, and Mounting Hardware

    2. SGSA-ML-L-LPQ20

      logo with r symbol

      Safety Grid System and LS Light Curtain, Accessory
      Mute Arm Kit: L Configuration Left Side
      Includes: One Sensor Arm with Two Q20PLPQ5 Sensors Installed
      One Reflector Arm with Two Reflectors Installed, and Mounting Hardware

    3. SGSA-MT-LPQ20

      logo with r symbol

      Safety Grid System and LS Light Curtain, Accessory
      Mute Arm Kit: T Configuration
      Includes: Two Sensor Arms with Two Q20PLPQ5 sensors installed on each arm
      Two Reflector Arms with Two Reflectors Installed on Each Arm, and Mounting Hardware

    4. SGSA-MX-LPQ20

      logo with r symbol

      Safety Grid System and LS Light Curtain, Accessory
      Mute Arm Kit: X Configuration
      Includes: Two Sensor Arms with One Q20PLPQ5 Sensor Installed on Each Arm
      Two Reflector Arms with One Reflectors Installed on Each Arm, and Mounting Hardware

    Add to My Library
    Added