• Back

  • MMD-TA-12B

    Item Detail MMD Series Muting Safety Relays
    MMD-TA-12B
    MMD-TA-12B
    MMD-TA-12B

    Certifications

    • NIPF NIPF7 Vol1 Sec12
    • CE

    Compatible Amplifiers

    Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.

    Accessories to Complete Your System

    Add all or individual items to your cart. More options available below.

    Power
    DC
    IP Rating
    IP20
    Device Type
    Safety Relay
    In-Series Diagnostics
    No
    Safety Module Type
    Muting Module
    Expandable
    No
    LCD Display
    No
    Dimension (H x W x D in mm)
    84 x 67.5 x 118
    Relative Humidity
    95% @ 50° C
    Max Operating Temperature ( °C)
    50
    Input Operation
    Simultaneous within 3.0 s
    Number of Safe Inputs
    2
    Input Configuration
    2 NC, 1 NC, or 2 PNP
    Safety Input - Dual Channel (Dry Contact)
    10-50 mA @ 15-30 V dc
    Safety Input - Dual Channel (Solid-State)
    10-50 mA @ 15-30 V dc
    Safety Input - Reset
    10-50 mA @ 15-30 V dc
    Independently Controlled Safe Outputs
    1
    Output Configuration
    1 OSSD Pair
    Non Safe Output Configuration
    1 PNP
    Non Safe Output Rating
    250 mA
    Safe Output Rating
    500 mA
    Splittable Safe Output
    No
    Mechanical Life (Operations in Millions)
    50
    Power Consumption
    0.25 A
    Response Time (ms)
    10 (max.)
    Supply Voltage
    24 V dc +/- 15%
    Terminal Type
    Screw
    Removable Terminals
    Yes
    Vibration
    10-55 Hz at 0.35 mm
    Electrical Life (Cycles @ VA)
    120,000 @ 1380 VA
    PL Rating
    e
    Safety Category Rating
    4
    SIL Rating
    3
    SISTEMA
    PFHd = 1.2 x 10-9
    Input Resistance
    400 Ω max. per channel
    E-Stops/Rope Pulls
    Yes
    Safety Mat
    No
    Motor Speed
    No
    Muting
    Yes
    Gate Switch (NC/NC) Input
    Yes
    Gate Switch (NC/NO) Input
    No
    Gate Switch (OSSD) Input
    Yes
    Light Curtains/Scanner with EDM Input
    Yes
    Light Curtains/Scanner without EDM Input
    Yes

    The following products are included with your order

    CAD Files

    Date
    Type
    Size
    MMD-TA-XB
    6 Mar 2019
    PDF
    409K
    MMD-TA-XB
    6 Mar 2019
    DXF
    904K
    MMD-TA-XB
    6 Mar 2019
    IGS
    7.5MB
    MMD-TA-XB
    6 Mar 2019
    STP
    4.5MB

    Technical Literature

    Date
    Type
    Size
    MMD-TA- 11B and MMD-TA-12B Muting Module
    26 Jun 2019
    PRODUCT MANUAL
    924K
    Machinery Directive 2006/42/EC Notice
    1 Dec 2016
    CERTIFICATION
    36K

    Certification

    Date
    Type
    Size
    DoC for MMD-TA-1XB
    27 Oct 2017
    CERTIFICATION
    276K
    MMD-TA-12B
    MMD-TA-12B
    Item Detail: MMD Series Muting Safety Relays

    Certifications

    • NIPF NIPF7 Vol1 Sec12
    • CE
    Add to My Library
    Added