QS30EDV Single-Point Window Teach

Transcript

This video will show how to set up QS30EDV Low Contrast sensor, which is designed to detect targets out to 1.4 m and to operate down to 300 ms.

Start off by aligning the sensor with the target.

Then press and hold the - button until the number 5 and 6 LED flash.

To set the window, double click the - button.

The sensor is now taught to detect within it's set window.

A higher number on the back of the sensor represents a stronger signal.

To increase the window size, click the + button.

Notice the number 8 LED represents the strongest signal and the number 1 LED represents the weakest signal.

If the sensor fails to teach, you will see the following condition.