SM-HA-5A
Certifications
Compatible Amplifiers
Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.
Accessories to Complete Your System
Add all or individual items to your cart. More options available below.
Specifications
- Power
- AC/DC Universal
- IP Rating
- IP20
- Device Type
- Safety Relay
- In-Series Diagnostics
- No
- Safety Module Type
- Safety Mat Module
- Expandable
- No
- LCD Display
- No
- Dimension (H x W x D in mm)
- 84 x 45 x 118
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature ( °C)
- 50
- Input Operation
- 4-Wire
- Number of Safe Inputs
- 1
- Input Configuration
- 2 NC
- Safety Input - Dual Channel (Dry Contact)
- 20-100 mA @ 12-30 V dc
- Safety Input - Reset
- 20-50 mA @ 12-30 V dc
- Independently Controlled Safe Outputs
- 1
- Output Configuration
- 4 NO
- Non Safe Output Configuration
- 1 NC, 2 PNP
- Non Safe Output Rating
- Relay - 5 A
- Safe Output Rating
- Relay - 6 A
- Splittable Safe Output
- No
- Mechanical Life (Operations in Millions)
- 20
- Power Consumption
- 4 W / 7 VA
- Recovery Time (ms)
- 350
- Response Time (ms)
- 35 (max.)
- Supply Voltage
- 230 V ac; 12-24 V dc
- Terminal Type
- Screw
- Removable Terminals
- Yes
- Vibration
- 10-60 Hz at 0.35 mm
- Electrical Life (Cycles @ VA)
- 150,000 @ 1500 VA
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 5.8 x 10-8
- Input Resistance
- 250 Ω max. per channel
- E-Stops/Rope Pulls
- No
- Safety Mat
- Yes
- Motor Speed
- No
- Muting
- No
- Gate Switch (NC/NC) Input
- No
- Gate Switch (NC/NO) Input
- No
- Gate Switch (OSSD) Input
- No
- Light Curtains/Scanner with EDM Input
- No
- Light Curtains/Scanner without EDM Input
- No
- Recovery Time
- 350