XS2RO
Certifications
Compatible Amplifiers
Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.
Accessories to Complete Your System
Add all or individual items to your cart. More options available below.
Specifications
- IP Rating
- IP20
- Device Type
- Safety Controller
- In-Series Diagnostics
- No
- Safety Module Type
- Output Module
- Expandable
- Yes
- LCD Display
- No
- Dimension (H x W x D in mm)
- 110 x 22.5 x 129
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature ( °C)
- 55
- Independently Controlled Safe Outputs
- 2
- Output Configuration
- 2 sets of 2 NO
- Non Safe Output Configuration
- 2 separate NC
- Non Safe Output Rating
- N/A
- Safe Output Rating
- Relay - 4 NO: 6A; 2 NC: 2.5A
- Splittable Safe Output
- No
- Mechanical Life (Operations in Millions)
- 40
- Power Consumption
- 0.15 A (outputs on)
- Response Time (ms)
- See Software Configuration Summary
- Terminal Type
- Screw
- Removable Terminals
- Yes
- Vibration
- 9-150 Hz at 1g occasional/0.5g continuous
- Electrical Life (Cycles @ VA)
- 50,000 @ full resistive load
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 7.6 x 10-10
- Gate Switch (NC/NC) Input
- No
- Gate Switch (NC/NO) Input
- No
- Gate Switch (OSSD) Input
- No
- Light Curtains/Scanner with EDM Input
- No
- Light Curtains/Scanner without EDM Input
- No