UM Series

Üniversal Input Emniyet Röleleri

UM module

Monitors a wide variety of safety and non-safety input devices:

  • Optical-based safeguarding devices, such as Safety Laser ScannersPositive-opening safety switches used for guard interlockingEmergency-stop devices, such as palm buttons and rope/cable pulls
  • Standard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travel

The safety inputs can monitor:+24V dc solid-state (PNP) outputs in single-channel or dual-channel hookup+24V dc source that is switched by hard/relay contacts in single-channel or dual-channel hookup

  • Standard sensors for non-safety applications, such as photoelectric monitoring position or end-of-travel
  • Tb>UM-FA-9A: Three normally open (N.O.) output switching channels for connection to control-reliable power interrupt circuits
  • UM-FA-11A: Two normally open (N.O.) and one normally closed (N.C.) output switching channels for connection to control-reliable power interrupt circuits
  • Automatic reset or monitored manual reset, depending on hookup
  • Design complies with Category 4 PLe (ISO 13849-1), SIL 3 (IEC 61508/IEC 62061), and Control Reliable (ANSI B11.19)
  • Safety Integrity Level (SIL) 3 (IEC 61508/62061)
  • Performance level (PL) e (ISO 13849-1)
  • For use in functional stop category 0 applications per ANSI NFPA 79 and IEC/EN 60204-1

  • Çok çeşitli emniyet veya emniyet dışı input'lara sahip cihazları izler:
    • Emniyet Lazer Tarayıcılar benzeri optik tabanlı koruma cihazları
      • Koruma kilitlemesi için kullanılan pozitifte açık emniyet switch'leri
        • Avuç içi butonlar ve halatlı/kablolu switch'ler gibi acil durdurma cihazları
        • Fotoelektrik pozisyon veya hareket sonu izleme gibi emniyet dışı uygulamalar için standart sensörler
      • Emniyet input'larla aşağıdakileri izlenebilir:
        • + Tek kanallı veya çift kanallı bağlantıda 24V DC solid-state (PNP) output'lar
          • + Tek kanallı veya çift kanallı bağlantıda sabit/röle kontakları ile anahtarlanan + 24 V DC kaynak
          • Fotoelektrik pozisyon veya hareket sonu izleme gibi emniyet dışı uygulamalar için standart sensörler
        • Tb>UM-FA-9A: Üç adet normalde açık (NO) output anahtarlama kanalı
        • Um-FA-11A: İki adet normalde açık (NO) ve bir normalde kapalı (NC) output anahtarlama kanalı
        • Bağlantıya göre otomatik sıfırlama veya izlenen manuel sıfırlama
        • Tasarım şu standartlarla uyumludur: Categori 4 PLe (ISO 13849-1), SIL 3 (IEC 61508/IEC 62061) ve Control Reliable (ANSI B11.19)
        • Safety Integrity Level (SIL) 3 (IEC 61508/62061)
        • Performance Level (PL) e (ISO 13849-1)
        • ANSI NFPA 79 ve IEC/EN 60204-1'e göre fonksiyonel durdurma kategorisi uygulamalarında kullanıma uygundur.

Teknik Literatür

Tarih
Tip
Boyut
UM-FA-xA Universal Input Safety Module
4 Nov 2025
Ürün Kullanma Klavuzu
752K

Broşürler ve Kataloglar

Tarih
Tip
Boyut
Safety Solutions Brochure
Safety Solutions Brochure
28 May 2026
Ürün Broşürü
13.7MB
Safety Overview Flyer
Safety Overview Flyer
15 Feb 2023
Ürün Broşürü
2.5MB
Tarih
Tip
Boyut
CN_Safety Solutions Brochure
安全解决方案
06/09/23
Ürün Broşürü
14.8MB

Ürün Seçimi

Yükleniyor...

Sonuçları Daralt

tüm filtreleri temizle

Output Configuration

  • (1)
  • (1)
Tümünü Görüntüle Daha Az Görüntüle
seçilen filtreler
  1. UM-FA-9A

    logo with r symbol

    Safety Relay Module for Safety Light Curtain/Scanner/E-Stop/Interlock
    Supply Voltage: 24 V ac/dc
    Safety Input: 1 Dual/Single Channel
    Safety Output: 3 NO, 6 A; Aux Output: None
    Terminal Block: Removable; Width: 22.5 mm
    Self-Checking Circuitry, Auto/Manual Reset

  2. UM-FA-11A

    logo with r symbol

    Safety Relay Module for Safety Light Curtain/Scanner/E-Stop/Interlock
    Supply Voltage: 24 V ac/dc
    Safety Input: 1 Dual/Single Channel
    Safety Output: 2 NO, 7 A; Aux Output: 1 NC, 7 A
    Terminal Block: Removable; Width: 22.5 mm