Spécifications
- Power
- AC/DC Universal
- IP Rating
- IP20
- Device Type
- Safety Relay
- In-Series Diagnostics
- No
- Safety Module Type
- Two-Hand Control Module
- Expandable
- No
- LCD Display
- No
- Dimension (H x W x D in mm)
- 84 x 22.5 x 118
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature ( °C)
- 50
- Input Operation
- Simultaneous <= 500 ms (500 ms typical)
- Number of Safe Inputs
- 1
- Input Configuration
- 2 x complementary (contact or PNP)
- Safety Input - Dual Channel (Dry Contact)
- 25 mA @ 24 V dc (1 NO / 1 NC per channel)
- Safety Input - Dual Channel (Solid-State)
- 25 mA @ 24 V dc (1 complementary PNP pair per channel)
- Independently Controlled Safe Outputs
- 1
- Output Configuration
- 2 NO
- Non Safe Output Rating
- N/A
- Safe Output Rating
- Relay - 6 A
- Splittable Safe Output
- No
- Mechanical Life (Operations in Millions)
- 20
- Power Consumption
- 3 W / 3 VA
- Response Time (ms)
- 35 (max.)
- Supply Voltage
- 24 V ac/dc +/- 15%
- Terminal Type
- Screw
- Removable Terminals
- Yes
- Vibration
- 10-55 Hz at 0.35 mm
- Electrical Life (Cycles @ VA)
- 1,000,000 @ 250 VA
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 1.5 x 10-9
- THC Rating
- IIIC
- Two-Hand Controls
- Yes
- Gate Switch (NC/NC) Input
- No
- Gate Switch (NC/NO) Input
- No
- Gate Switch (OSSD) Input
- No
- Light Curtains/Scanner with EDM Input
- No
- Light Curtains/Scanner without EDM Input
- No