Smart, Scalable Safety Control
The Safety Controller is the Backbone of Your Safety System
Safety control is a critical and a required part of any safety system. It ensures that your safety measures 1) do not fail, or 2) if failure is inevitable, fail in a predictably safe way.
A safety controller is often an ideal safety control solution, because it provides more functionality than a safety relay, at a lower cost than a safety PLC. In addition, a smart, scalable safety controller can expand with your needs as well as enable remote monitoring of your machine safety systems.
Designing a Smart Machine Safety System That Expands With Your Business
There are many different types of safety devices that all work together to protect workers from injury and protect machines from damage. A safety system can quickly become complex and daunting, with many areas to protect and many devices to implement and manage.
However, an easy-to-use and flexible safety controller will make it much easier to get your system up and running quickly with minimal downtime and will allow you to easily expand and adapt to future needs. Note that for simple applications, a full-feature safety controller may not be necessary. In these cases, a safety relay provides reliable safety control with minimal complexity.
Please note: The information on this page is meant for educational purposes only and is accurate as of the time of publication. Always consult a safety expert about your specific application prior to implementing any machine safety measures.
Guards Multiple Points and Expands to Meet Changing Requirements
Safeguarding multiple points across a large machines and assembly lines can be challenging because of the variety of hazards present. With multiple zones and dozens of safety devices, wiring with traditional relay modules can become complicated. The result is high costs and long installation times to create the appropriate safety logic and circuits.
An expanable safety controller provides a simpler solution to safeguard hazards, protect personnel, and scale to meet the needs a very complex safety applications. Also, a safety controller that can expand when you need it allows for the required agility to meet deadlines and implement changes quickly.
Saves time and costs with minimal learning curve
Intuitive programming saves time and costs. An icon-based, drag-and-drop user interface reduces the learning curve and speeds up commissioning, and it makes it easy to quickly modify and update the configuration when changes are needed. Note that many safety controllers have password protection to ensure only authorized users can make changes, reducing the risk of operators bypassing the system.
Furthermore, look for a safety controller interface that automatically generates wiring diagrams to speed up installation. In addition, a controller with live simulation will allow users to test configurations and changes quickly before implementation.
Monitor Safety Devices Remotely
Real time fault monitoring allows quick identification of problems. Look for a safety controller that can communicate with your PLC via Profinet, Modbus, TCP/IP, PCCC, etc. This allows you to remotely monitor your safety devices and will ensure that you are notified in real time when there is an issue with the safety system. Also, with configurable IO, inputs can be changed to non-safe outputs to control indicatior lights for local notification of a fault.
For example, XS26 and SC26 safety controllers can communicate up to 256 virtual status updates to a PLC or HMI that can be stored and tracked for future analysis. Furthermore, these controllers can also receive up to 80 virtual non-safety inputs to remotely turn safety devices or indicators on and off, enable mute functions, cancel off-delays, initiate a reset, and accomplish other tasks quickly and easily in the HMI without complicated programming.
Expandable Safety Controller
Le contrôleur de sécurité extensible XS26-2 convient à un large éventail de machines, y compris les grosses machines exécutant plusieurs processus.
- Programmation en quelques minutes à l'aide d'un logiciel de configuration convivial
- Possibilité d'ajout de 8 modules d'extension d'E/S en fonction de l'évolution des besoins d'automatisation
- Afficheur en temps réel innovant pour le diagnostic et le control des E/S
- Les modèles Ethernet, à l'aide de l'interface PC, peuvent être configurés pour avoir jusqu'à 256 sorties d'état virtuelles.
Safety Controllers
Peu encombrant et doté de fonctions logiques booléennes, le SC26-2 est simple à utiliser, flexible et efficace.
- Surveillance d'un large éventail de dispositifs d'entrée, par exemple des boutons d'arrêt d'urgence, des interrupteurs à câble, des dispositifs d'activation, des dispositifs d'arrêt d'urgence (arrêt de sécurité), des portes ou des systèmes de protection à verrouillage, des capteurs optiques, des commandes bimanuelles et des tapis de sécurité
- Fonctions logiques booléennes pour une programmation plus souple
- Environnement de programmation intuitif pour simplifier l'implémentation
- Blocs fonction de sécurité préconfigurés, y compris les dispositifs de commande bimanuelle, de muting et d'activation pour simplifier la programmation des applications
- Contrôleur de base permettant de configurer 8 des 26 entrées en tant que sorties afin d'optimiser l'utilisation des bornes