SLLR40-1330-S
Certifications
Amplificateurs compatibles
Dans les cas applicables, la portée maximale des fibres en mode barrière dépend également de la longueur de la fibre.
Spécifications
- IP Rating
- IP65, IP67
- Defined Area Height Range (mm)
- >1300
- Max Operating Range (m)
- >8 - <=20
- Primary Housing Material
- Aluminum
- Safety Level
- Type 4
- Effective Aperture Angle
- Type 4 Per IEC 61496-2
- Connector Type
- Removable Disconnect
- Defined Area Height (mm)
- 1330
- Dimensions WxD (mm)
- 36 x 45
- Overall Length (mm)
- 1333
- External Monitoring Device
- 1 Channel
- Fixed Blanking
- No
- Housing Finish
- Black Anodized
- Operating Distance (m)
- 0.1 - 12
- Operating Voltage
- 24 V dc +/- 15%
- Operating Temperature
- -20 to +55 deg. C; RH 95%
- PL Rating
- Ple
- Recovery Time
- 53 / 179
- Resolution (mm)
- 40
- Reduced Resolution
- No
- SIL Rating
- SIL3; CL3
- Electrical Safety Class
- III
- Scan Code
- Selectable
- Shock
- 10g at 16ms (6000 cycles)
- Short Protection
- Yes
- System Type
- Receiver
- Vibration
- 10-55 Hz at 0.35 mm
- Auxiliary Output
- No
- Fault Output
- Yes
- Housing Material
- Aluminum; Zinc; Acrylic
- OSSD Rating
- 24 V dc at 0.5 A each
- Supply Current
- 101 mA Typical
- Trip/Latch Output
- Trip
- Test Input
- No
- Feature: End-to-End Sensing
- Yes