| Range | 30 to 300 mm |
|---|---|
| Supply Voltage and Current | 10 to 30V dc (10% max. ripple) @ 65 mA max (exclusive of load) |
| Ultrasonic Frequency | 300 kHz
Rep. rate:2.5 milliseconds |
| Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
| Output Configuration | Bipolar:One NPN (current sinking) and one PNP (current sourcing). SPST solid-state switch conducts when target is sensed within sensing window. |
| Output Rating | 100 mA max.
OFF-state leakage current:less than 5 µA Output saturation: NPN:less than 200 mV @ 10 mA; less than 600 mV @ 100 mA
PNP:less than 1.2V @ 10 mA; less than 1.6V @ 100 mA
|
| Output Protection | Protected against short circuit conditions |
| Output Response Time | 5 milliseconds |
| Delay at Power-up | 300 milliseconds |
| Temperature Effect | 0.02% of distance/° C |
| Repeatability | 0.5 mm |
| Hysteresis | 0.7 mm |
| Minimum Window Size | 5 mm |
| Adjustments | Sensing window limits:TEACH-Mode programming of near and far window limits may be set using the push buttons or remotely using TEACH input. |
| Indicators | Power/Signal Strength (Red/Green): Green:target is within sensing range
Red:target is outside sensing range
OFF:sensing power is OFF
TEACH/Ouput indicator (Yellow/Red):Yellow:target is within taught limits
Red:sensor is in TEACH mode
OFF:target is outside taught window limits
|
| Remote TEACH | Impedance:12 k ohms |
| Construction | Threaded barrel:thermoplastic polyester Push-button housing:ABS/PC Push-button:santoprene Lightpipes:acrylic |
| Environmental Rating | Leakproof design, rated IEC IP7; NEMA 6P |
| Connections | 5-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-20° to +60° C Relative humidity:100% |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |
| Temperature Warmup Drift | Less than 1.7% of sensing distance upon power-up |
| Application Note | Objects passing inside the specified near limit may produce a false response. |
Industry solutions, application tips, new products, quick video tutorials, trends.
Subscribe Now »Is your line competitive? Innovative, high-quality solutions for every phase of production. Enjoy increased accuracy, greater productivity, cost savings.
Learn more »Banner has more than 2,000 distributors worldwide - ready to help you.