Long-range programmable ultrasonic sensor with dc voltage and two discrete outputs
| Supply Voltage and Current | 10 to 30V dc (10% max. ripple); 100 mA max. @ 10V, 40 mA max @ 30V (exclusive of load) |
|---|---|
| Range | 200 mm to 8 m |
| Ultrasonic Frequency | 75 kHz
Rep. rate:96 milliseconds |
| Supply Protection Circuitry | Protected against reverse polarity and transient overvoltages |
| Output Configuration | Dual NPN (current sinking) or PNP (current sourcing), selectable via DIP switch |
| Output Rating | 150 mA max.
OFF-state leakage current:less than 5 µA Output saturation: NPN:less than 200 mV @ 10 mA; less than 650 mV @ 150 mA
PNP:less than 1.2V @ 10 mA; less than 1.65V @ 150 mA
|
| Output Protection | Protected against short circuit conditions |
| Output Response Time | 100 to 1600 milliseconds |
| Delay at Power-up | 1.5 seconds |
| Temperature Effect | Uncompensated:0.2% of distance/° C Compensated:0.02% of distance/° C |
| Repeatability | 1.0 mm |
| Hysteresis | 5 mm |
| Minimum Window Size | 20 mm |
| Adjustments | Sensing window limits:TEACH-Mode programming of near and far window limits may be set using the push buttons or remotely using TEACH input. |
| Indicators | Green Power ON LED:indicates power is ON Red Signal LED:indicates target is within sensing range, and the condition of the received signal TEACH/Output indicator (bicolor Yellow/Red): Yellow:target is within taught limits
Red:sensor is in TEACH mode
OFF:target is outside taught window limits
|
| Remote TEACH | To TEACH:connect gray or yellow wire to 0 to +2V dc; impedance 12 k ohms |
| Construction | Transducer:ceramic/epoxy composite Housing:ABS/Polycarbonate Membrane switch:polyester Lightpipes:acrylic |
| Environmental Rating | Leakproof design, rated IEC IP7; NEMA 6P |
| Connections | 5-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro- or Mini-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-20° to +70° C Relative humidity:100% |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |
| Temperature Warmup Drift | Less than 0.890% of sensing distance upon power-up with Temperature Compensation enabled |
| Application Note | Objects passing inside the specified near limit (200 mm) may produce a false response. |
Industry solutions, application tips, new products, quick video tutorials, trends.
Subscribe Now »Is your line competitive? Innovative, high-quality solutions for every phase of production. Enjoy increased accuracy, greater productivity, cost savings.
Learn more »Banner has more than 2,000 distributors worldwide - ready to help you. Enter a U.S. zip code