U-GAGE T30U—Pump/Level Control

Product image

Overview

  • Provides 12 to 24V dc supply voltage with two NPN or PNP outputs, depending on models
  • Offers dual-discrete outputs for setting independent near/far limits or a setpoint centered in the window, for either or both outputs
  • Includes switching logic for fill-level control and web tensioning control
  • Features independently programmable outputs
  • Housed in T-style right-angle housing with 30 mm threaded nose
  • Available with range of 150 mm to 1 m with a 48 millisecond response time, or 300 mm to 2 m with a 96 millisecond response time
  • Available in chemically resistant models with a Teflon coating to protect the transducer
  • Simplifies setup with push-button and remote TEACH-mode programming

Product Specifications

Supply Voltage and Current12 to 24V dc (10% max. ripple) @ 90 mA (exclusive of load)
Range“A” suffix models:
Near limit:150 mm min.
Far limit:1 m max.
“B” suffix models:
Near limit:300 mm min.
Far limit:2 m max.
“-CRFV” suffix models:
Near limit:300 mm min.
Far limit:1.5 m max.
Supply Protection CircuitryProtected against reverse polarity and transient voltages
Output ConfigurationSPST solid-state switch conducts when target is sensed within sensing window; choose NPN (current sinking) or PNP (current sourcing) models
Output Rating100 mA max. per sensor OFF-state leakage current:less than 10 µA
ON-state saturation voltage:less than 1V @ 10 mA; less than 1.5V @ 100 mA
Output ProtectionProtected against false pulse on power-up and continuous overload or short-circuit of outputs
Output Response Time“A” suffix models:48 milliseconds
“B” suffix models:96 millliseconds
Sensing PerformanceSpecified using a 10 x 10 cm aluminum target @ 25° C under fixed sensing conditions. Repeatability:±0.25% of measured distance
Minimum window size:10 mm
Hysteresis:2.5 mm
AdjustmentSensing window limits:TEACH-mode programming of near and far window limits may be set using membrane push buttons on sensor or remotely using TEACH input. Window limits may be programmed separately or together.
Indicators4 LED indicators:
In RUN mode:
Green ON steady:power ON, RUN mode
Green flashing:output overloaded
Red flashing:relative received signal strength
Yellow ON steady:output conducting
In PROGRAM mode:
Green OFF:PROGRAM mode
Red flashing:relative received signal strength
Yellow ON steady:ready for first window limit
Yellow flashing:ready for second window limit
Yellow OFF:not teaching this output
Construction Molded reinforced thermoplastic polyester housing
Environmental RatingLeakproof design is rated IEC IP67; NEMA 6P
Connections5-conductor 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Euro-style quick-disconnect fitting. QD cables are ordered separately.
Operating ConditionsTemperature:-20° to +70° C
Relative humidity:100%
Vibration and Mechanical ShockAll models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave.
Application NoteObjects passing inside the specified near limit will produce a false response.

Sign up for eNews

Industry solutions, application tips, new products, quick video tutorials, trends.

Subscribe Now »

Worldwide Distributors

Banner has more than 2,000 distributors worldwide - ready to help you.


Find international distributors