| Supply Voltage and Current | 10 to 30V dc (10% maximum ripple within specified limits) Supply current (exclusive of load current): 75 mA max @ 10V dc 35 mA @ 30V dc |
|---|---|
| Supply Protection Circuitry | Protected against reverse polarity and transient over voltages |
| Output Configuration | Single output: one current sourcing (PNP) or one current sinking (NPN) open-collector transistor by model |
| Output Rating | ON-state load current: 100 mA max OFF-state leakage current: NPN < 200 microamps; PNP < 10 microamps (see Application Note 1) NPN Saturation: < 1.6V at 100 mA PNP Saturation: < 3.0V at 100 mA |
| Output Protection Circuitry | Protected against false pulse on power up and continue overload or short-circuit of output |
| Output Response Time | 50 microseconds Note: 1 second delay on power-up; output does not conduct during this time |
| Repeatability | 15 microseconds |
| Tri-Color LED Sensing Image | Rectangular: 1.2 mm x 3.8 mm (0.05 |
| Construction: | Housing: Zinc alloy die-cast and steel housing with black painted finish and o-ring sealed lens and lens port cap Lens: Acrylic Lens port cap and lens holder: ABS Push-buttons: Thermoplastic elastomer Labels: Polycarbonate |
| Adjustments | MODE Push-button Selects Operating Mode TEACH Push-button Initiate Teach from STATIC or DYNAMIC Mode Both Push-buttons >2 s Enter Sensor Set-up (only accessible from RUN Mode) Remote Input (gray wire) Input for remote Set-up of the sensor (PLC compatible) |
| Connections | PVC-jacketed 5 conductor 2 m (6.5') or 9 m (30') cable with internal strain relief Integral 5-pin Euro-style QD fitting 150 mm (6 |
| Operating Conditions | Temperature: -10° to -55° C (+14° to 131° F) Storage Temperature: -20° to +80° C (-4° to 185° F) Maximum Relative Humidity: 90% at 50° C (non-condensing) |
| Environmental Rating | IEC IP67 |
| Vibration and Mechanical Shock | All models meet IEC 68-2-6 and IEC 68-2-27 testing criteria |
| Application Notes | 1. NPN OFF-state leakage current is < 200 µA for load impedances > 3kΩ or optically isolated loads. For load current of 100 mA, leakage is < 1% of load current. 2. Do not mount the sensor directly perpendicular to shiny surfaces; position it at approximately a 15° angle in relation to the sensing target (see Installation Notes). 3. Minimize web or product |