• Retour

  • GM-FA-10J

    Informations sur l'article ES Series E-Stop and GM Series Guard Monitoring Safety Relays
    GM-FA-10J
    GM-FA-10J
    GM-FA-10J

    Certifications

    • QUKQ QUKQ7 Vol1 Sec3
    • NISD Vol1 Sec8
    • 1228215
    • CE

    Amplificateurs compatibles

    Dans les cas applicables, la portée maximale des fibres en mode barrière dépend également de la longueur de la fibre.

    Power
    AC/DC Universal
    IP Rating
    IP20
    Device Type
    Safety Relay
    In-Series Diagnostics
    No
    Safety Module Type
    Gate Monitoring Module
    Expandable
    No
    LCD Display
    No
    Dimension (H x W x D in mm)
    84 x 22.5 x 118
    Relative Humidity
    90% @ 50° C
    Max Operating Temperature ( °C)
    50
    Input Operation
    Simultaneous within 3.0 s
    Number of Safe Inputs
    2
    Input Configuration
    1 complementary or 2 x complementary (contact)
    Safety Input - Dual Channel (Dry Contact)
    20-50 mA @ 15-30 V dc
    Safety Input - Reset
    20 mA @ 12 V dc (dry contact only)
    Independently Controlled Safe Outputs
    1
    Output Configuration
    2 NO
    Non Safe Output Rating
    N/A
    Safe Output Rating
    Relay - 6 A
    Splittable Safe Output
    No
    Mechanical Life (Operations in Millions)
    50
    Power Consumption
    3 W / 3 VA
    Recovery Time (ms)
    250
    Response Time (ms)
    35 (max.)
    Supply Voltage
    24 V ac/dc +/- 15%
    Terminal Type
    Screw
    Removable Terminals
    Yes
    Vibration
    10-55 Hz at 0.35 mm
    Electrical Life (Cycles @ VA)
    1,000,000 @ 250 VA
    PL Rating
    e
    Safety Category Rating
    4
    SIL Rating
    3
    SISTEMA
    PFHd = 1.54 x 10-9
    Input Resistance
    270 Ω max. per channel
    E-Stops/Rope Pulls
    Yes
    Safety Mat
    No
    Motor Speed
    No
    Muting
    No
    Gate Switch (NC/NC) Input
    No
    Gate Switch (NC/NO) Input
    Yes
    Gate Switch (OSSD) Input
    No
    Light Curtains/Scanner with EDM Input
    No
    Light Curtains/Scanner without EDM Input
    No
    Recovery Time
    250

    Les produits suivants sont inclus dans votre commande

    Fichiers CAD

    Date
    Type
    Size
    GM-FA/ES-FA
    20 Apr 2022
    STP
    1.1MB
    GM-FA/ES-FA
    22 Mar 2016
    DXF
    458K
    GM-FA/ES-FA
    22 Mar 2016
    PDF
    158K
    GM-FA/ES-FA
    20 Apr 2022
    IGS
    1.6MB

    Littérature technique

    Date
    Type
    Size
    GM-FA-10J Gate Monitoring Module (24 VAC/VDC, Single or Dual Inputs)
    25 Jul 2023
    DATA SHEET
    1.1MB

    Certifications

    Date
    Type
    Size
    DoC for AT-FM-10K/GM-FA-10J
    29 Dec 2022
    CERTIFICATION
    4.9MB
    GM-FA-10J
    GM-FA-10J
    Informations sur l'article: ES Series E-Stop and GM Series Guard Monitoring Safety Relays

    Certifications

    • QUKQ QUKQ7 Vol1 Sec3
    • NISD Vol1 Sec8
    • 1228215
    • CE
    Ajouter à ma bibliothèque
    Ajouté