Fibras Ópticas para Altas Temperaturas
High temp fiber optics are used in situations where the temperature is above a certain limit for most plastic fibers. These are usually used in thermal process applications and Banner offers the widest selection of plastic and glass fibers for high temperature situations.
- For high temp applications above 100° C
- Thermal process applications
- For sensing near manufacturing ovens
- Manufacturing of solar panels, colored glass and ceramics
- Widest selection of plastic and glass fibers for high temp applications
La fibra óptica de alta temperatura se usa en situaciones donde la temperatura está por encima de un límite determinado para la mayoría de las fibras plásticas. Estos se usan generalmente en aplicaciones de procesos térmicos y Banner ofrece la más amplia selección de fibras plásticas y de vidrio para situaciones de alta temperatura.
- Para aplicaciones con altas temperaturas, por encima de 100 ° C
- Aplicaciones con procesos térmicos
- Para la detección cerca de hornos de fabricación
- Fabricación de paneles solares, vidrio coloreado y cerámica
- La más amplia selección de fibras ópticas de plástico y vidrio para aplicaciones con alta temperatura
-
BT23S
Diffuse Mode Bifurcated Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Threaded sensing tip -
IAT23S
Opposed Mode Individual Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Right angle threaded sensing tip -
IT23S
Opposed Mode Individual Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Threaded sensing tip -
IA23S
Opposed Mode Individual Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Right angle sensing tip -
ITA23S
Opposed Mode Individual Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Threaded & angled sensing tip -
BAT23S
Diffuse Mode Bifurcated Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Right angle threaded sensing tip -
ITETA1.53S
Glass Fiber Opposed Mode0.91 m long
2.29 mm dia. Bundle
Stainless Steel Sheath
5/16x24 Thread
4.75 mm Probe, Side Exit -
BA23S
Diffuse Mode Bifurcated Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Right angle sensing tip -
IA.81.5ST5ETAMT
Glass Fiber
Individual 0.05 in Bundle
Tight Right-Angle Tip
Stainless Sheathing 18 in
Stainless Terminated For Plastic Fiber Sensors excluding D10 -
IAT43ST5TA-VL
Glass Fiber
Opposed Mode 1 mm dia. Bundle
M4 Threaded Right-Angle With M2.5 Tip
Stainless Sheathing 1 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
BTA23S
Diffuse Mode Bifurcated Glass Fiber 36 long
0.125 dia. Bundle
Stainless Steel Sheath
Threaded & angled sensing tip -
IA1.53SMTA
Glass Fiber Opposed Mode0.91 m long
2.29 mm dia. Bundle
Stainless Steel Sheath
6.35 mm Probe, Side Exit -
BR23S
Glass Fiber
Diffuse Mode 9.7 mm x 0.81 mm Array Bundle
Stainless Steel Sheathing
0.91 m long
25.4 mm x 19 mm Plastic Rectangle Sensing Tip -
IA1.53SMETA
Glass Fiber Opposed Mode0.91 m long
2.29 mm dia. Bundle
Stainless Steel Sheath
4.75 mm Probe, Side Exit -
IR2.53S
Opposed Mode Individual Glass Fiber 36 long
0.156 dia. Bundle
Stainless Steel Sheath
Rectangular sensing tip -
BF23P
Diffuse Mode Bifurcated Glass Fiber 36 long
0.125 dia. Bundle
PVC Sheath
Ferruled sensing tip 0.5 long -
IR23S
Glass Fiber Opposed Mode0.91 m long
3.18 mm dia. Bundle
Stainless Steel Sheath
Rectangle Sensing Tip
0.81 mm x 9.7 mm array -
BR2.53S
Glass Fiber
Diffuse Mode 38.1 mm x 0.25 mm Array Bundle
Stainless Steel Sheathing
0.91 m long
51 mm x 38 mm Rectangle Sensing Tip -
IR2.53SMRAMP
Opposed Mode Individual Glass Fiber 0.91 m long
3.96 mm dia. Bundle
Stainless Steel Sheath
Rectangular Sensing Tip; Side Exit Array
38.1 mm Length x 0.25 mm Width -
PBFM46UHTMLR
Plastic Fiber, Diffuse Reflective,Core Dia.: 1 mm; High Temp. Fiber Length 2 m
Ferrule, PEEK
Free cut -
IA.31.7ST5ETA
Glass Fiber
Opposed Mode 0.5 mm dia. Bundle
Tight Right-Angle Tip With Flats
Stainless Sheathing 0.51 m Long
Terminated For Plastic Fiber Sensors -
IT46ST5-VL
Glass Fiber
Opposed Mode 1 mm. dia. Bundle
M4 Threaded Tip With M2.5
Stainless Sheathing 2 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
IMT.756.6S-HT
Glass Fiber Opposed Mode 2 m long
1.27 mm dia. Bundle
Stainless Steel Sheath
M4 & M2.5 Thread
Terminated for use in Plastic Fiber Sensors
Max. Operating Temperature 315C at Threaded Tip -
BT21.5SM900
Diffuse Mode Bifurcated Glass Fiber 0.46 m long
3.18 mm dia. Bundle
Stainless Steel Sheath
Stainless Steel Threaded Snsing Tip
Max. Operating Temperature at Threaded Tip 482 degree C
No Epoxy Used in Sensing Tip -
TGR-.38MSSMVO
5/16 x 24 Threaded Stainless Housing
Glass Rod 0.38 in Long
Supplied with Fluoroelastomer O-Ring -
BA1.53SMETA
Glass Fiber
Diffuse Mode 2.29 mm dia. Bundle
Stainless Steel Sheathing
0.91 m long
25.4 mm long Probe, Side Exit sensing -
IAT46ST5TA-VL
Glass Fiber
Opposed Mode 1 mm. dia. Bundle
M4 Threaded Right-Angle With M2.5 Tip
Stainless Sheathing 2 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
IT43ST5-VL
Glass Fiber
Opposed Mode 1 mm. dia. Bundle
M4 Threaded Tip With M2.5
Stainless Sheathing 1 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
IAM.752S
Glass Fiber Opposed Mode 0.61 m long
1.17 mm dia. Bundle
Stainless Steel Sheath
1.5 mm dia. Angled Probe -
IT113.2SMT5M900
Glass Fiber
Opposed Mode
1.5 mm Bundle
5/16x24 Threaded Tip
Stainless Sheathing 4 m Long
Terminated For Plastic Fiber Sensors
Max. Operating Temperature at Sensing tip 482 deg. C -
BM.752S
Glass Fiber
Diffuse Mode 1.17 mm dia. Bundle
Stainless Steel Sheathing
.61 m long
25.4 mm long Sensing Probe -
BT63ST5-VL
Glass Fiber
Bifurcated 1.5 mm Bundle
M6 Threaded Tip
Stainless Sheathing 1 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
BAM.752S
Glass Fiber
Diffuse Mode 1.17 mm dia. Bundle
Stainless Steel Sheathing
0.61 m long
25.4 mm long Angled Sensing Probe -
BAT16.6ST5MTA
Glass Fiber
Bifurcated 0.06 in Bundle
M6 Threaded Right-Angle Tip
Stainless Sheathing 79 in
Terminated For Plastic Fiber Sensors -
BT1.56ST5M900
Glass Fiber: Diffuse Mode
2.29 mm Bundle; 5/16x24 Threaded Tip
Stainless Sheathing 1.83 m long
Terminated For Plastic Fiber Sensors
Max. Operating Temperature at Sensing tip 482 deg. C -
BA1.53SMTA
Diffuse-Mode Bifurcated Glass Fiber 36 long
0.09 dia. Bundle
Stainless Steel Sheath
Tight Right-Angle sensing tip -
BMT16.6S-HT
Glass Fiber
Diffuse Mode 1.57 mm dia. Bundle, Optically Isolated E&R Bundles
Stainless Steel Sheathing
2 m long
M4 Threaded Sensing Tip
Terminated for use in Plastic Fiber Sensors
Max. Operating Temp. at Threaded Tip 315 C -
BTETA1.53S
Glass Fiber
Diffuse Mode 2.29 mm dia. Bundle
Stainless Steel Sheathing
0.91 m long
5/16x24 Thread with 25.4 mm long Probe, Side Exit sensing -
IF23P
Opposed Mode Individual Glass Fiber 36 long
0.125 dia. Bundle
PVC Sheath
Ferruled sensing tip 0.5 long -
BMP.753P
Glass Fiber
Diffuse Mode 1.17 mm dia. Bundle
PVC over Moncoil Sheathing
0.91 m long
25.4 mm long Sensing Probe -
IAT22PMSS
Opposed Mode Individual Glass Fiber 24 in long
0.125 dia. Bundle
PVC Sheath
Right angle threaded sensing tip
Stainless Thread -
IAT26SMVF1.1X.8
Glass Fiber
Individual 0.125 in Dia. Bundle
Right-Angle with 5/16 - 24 Threaded Tip
Stainless Sheathing 72 in
For use in Vacuum/No Epoxy Used -
IM.752S
Glass Fiber Opposed Mode 0.61 m long
1.17 mm dia. Bundle
Stainless Steel Sheath
1.5 mm dia. Probe -
IT16SMT5M900
Glass Fiber
Opposed Mode
1.5 mm Bundle
5/16x24 Threaded Tip
Stainless Sheathing 1.83 m Long
Terminated For Plastic Fiber Sensors
Max. Operating Temperature at Sensing tip 482 deg. C -
BAT66ST5TA-VL
Glass Fiber
Bifurcated 0.06 in Bundle
M6 Threaded Right-Angle Tip
Stainless Sheathing 2 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
BF212S
Diffuse Mode Bifurcated Glass Fiber 3.66 m long
3.18 mm dia. Bundle
Stainless Steel Sheath
Ferruled sensing tip 12.7 mm long -
BMT.442P
Glass Fiber
Diffuse Mode 1.17 mm dia. Bundle
PVC over Moncoil Sheathing
0.91 m long
#8-32 Threaded Sensing Tip -
BT66ST5-VL
Glass Fiber
Bifurcated 1.5 mm Bundle
M6 Threaded Tip
Stainless Sheathing 2 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
IMT.442P
Glass Fiber Opposed Mode 0.61 m long
.69 mm dia. Bundle
#8-32 Brass Thread
PVC over Monocoil Sheath -
IR2.56.5SMRAMP
Opposed Mode Individual Glass Fiber 78 long
0.156 dia. Bundle
Stainless Steel Sheath
Rectangular sensing tip; side exit -
IT.83.3ST5M6
Glass Fiber
Individual 0.05 in Bundle
M6 Threaded Tip
Stainless Sheathing 39 in
Terminated For Plastic Fiber Sensors -
BAT16.6ST5TAMT
Glass Fiber
Bifurcated 0.06 in Bundle
M6 Threaded Right-Angle Tip
Stainless Sheathing 79 in
StainlessTermination, Not for use in D10 sensor -
BAT220SM900
GLASS FIBER
BIFURCATED 3.18 MM BUNDLE
6.1 m LONG STAINLESS SHEATHING
ANGLE W/5/16-24 THREADED SENSING END TIP
NO EPOXY ON SENSING END 482C/900F -
BAT63ST5TA-VL
Glass Fiber
Bifurcated 0.06 in Bundle
M6 Threaded Right-Angle Tip
Stainless Sheathing 1 m Long
Terminated For Plastic Fiber Sensors
Vantage Line -
BT11SM8M900
Glass Fiber
Diffuse Mode
.3 m long
3.18 mm dia. Bundle
Stainless Steel Sheath
M8 Threaded sensing tip
Max. Operating Temperature at Sensing End 480C -
BT13.5ST5
Glass Fiber
Bifurcated 0.06 in Bundle
5/16-24 Threaded Tip
Stainless Sheathing 42 in
Terminated For Plastic Fiber Sensors -
BT16SMTGRMLSD
Diffuse Glass Fiber assembly
1.83 m long
1.58 mm dia. Bundle
Stainless Steel Sheath
5/16-24 Brass Threaded Tip
Attached Modfied SS-4-VCR-P Fitting for Liquid Level Sensing with 19 mm Clad Glass Rod and Kalrez oring. Terminated for glass fiber sensors -
BTETA1.58SM600
Glass Fiber
Bifurcated 0.09 in Bundle
Tight Right-Angle Tip
Stainless Sheathing 96 in
Max.Operating temp. at tip 600F -
BTETA1.59S
Glass Fiber
Diffuse Mode 2.29 mm dia. Bundle
Stainless Steel Sheathing
2.74 m long
5/16x24 Thread with 25.4 mm long Probe, Side Exit sensing -
IA.82.5PT5
Glass Fiber
Opposed Mode 1.27 mm dia. Bundle
Right-Angle Tubular Probe
PVC Over Monocoil Sheathing 0.76 m Long
Terminated For Plastic Fiber Sensors -
IA.83.3ST5ETA
Glass Fiber
Opposed Mode 1.27 mm dia. Bundle
Tight Right-Angle Tip
Stainless Sheathing 1 m Long
Terminated For Plastic Fiber Sensors -
IA26SM600
Opposed Mode Individual Glass Fiber 1.83 m long
3.18 mm dia. Bundle
Stainless Steel Sheath
Right angle sensing tip -
IMP.753P
Glass Fiber
Opposed Mode 1.17 mm dia. Bundle
PVC over Moncoil Sheathing
0.91 m long
25.4 mm long Sensing Probe -
IMT.448P
Glass Fiber
Opposed Mode
Bundle Dia.: 0.027 in.
PVC w/Monocoil Sheath 96 in long
#8-32 Threaded End Tip
Terminated for Glass Fiber Sensors -
IMT.752S-HT
Glass Fiber Opposed Mode 0.61 m long
1.27 mm dia. Bundle
Stainless Steel Sheath
M4 & M2.5 Thread
Terminated for use in Plastic Fiber Sensors
Max. Operating Temperature 315C at Threaded Tip -
IMT.753SMVF
Glass Fiber Opposed Mode0.91 m long
1.27 mm dia. Bundle
Stainless Steel Sheath
M4 & M2.5 Thread
Vacuum Feed Through Compatible -
IR13ST5AL7.6
Glass Fiber Opposed Mode
1 m long
Stainless Steel Sheath
Rectangle Sensing Tip
0.25 mm x 7.62 mm array
Max. Operating Temperature at Sensing Tip, 315C
Terminated for use in Plastic Fiber Sensors -
IT.86.6ST5M6
Glass Fiber
Individual 1.3 mm Bundle
M6 Threaded Tip
Stainless Sheathing
2 M Long
Terminated For Plastic Fiber Sensors -
IT2.56.6SM8MMT
Opposed Mode Individual Glass Fiber 2 m long
3.96 mm dia. Bundle
Stainless Steel Sheath
Mounting Tube and Threaded sensing tip -
PBE415UTMLLPHT1
Plastic Fiber, Diffuse Reflective
Core Dia.: 1 mm; Fiber Length 5 m
Encapsulated
Chemical Resistant, Free cut -
PBE46UTMLLPHT1
Plastic Fiber, Diffuse Reflective
Core Dia.: 1 mm; Fiber Length 2 m
Encapsulated
Chemical Resistant, Free cut