ES-FA-11AA

Detalle del Producto ES Series E-Stop and GM Series Guard Monitoring Safety Relays
ES-FA-11AA
ES-FA-11AA
ES-FA-11AA

Certificaciones

  • NISD NISD7 Vol1 Sec5
  • 2019010305230351
  • CE

Amplificadores Compatibles

Donde sea aplicable, el rango máximo para modelos opuestos también depende de la longitud de la fibra.

Device Type
Safety Relay
Safety Module Type
Emergency Stop Module
LCD Display
No
Expandable
No
Dimension (H x W x D in mm)
84 x 22.5 x 118
Relative Humidity
90% @ 50° C
Max Operating Temperature ( °C)
50
Input Operation
Simultaneous or Concurrent
Number of Safe Inputs
1
Input Configuration
2 NC or 1 NC
Safety Input - Dual Channel (Dry Contact)
10-20 mA @ 12 V dc
Safety Input - Reset
20 mA @ 12 V dc (dry contact only)
Independently Controlled Safe Outputs
1
Output Configuration
2 NO
Non Safe Output Configuration
1 NC
Non Safe Output Rating
Relay - 7 A
Safe Output Rating
Relay - 7 A
Splittable Safe Output
No
Mechanical Life (Operations in Millions)
20
Power Consumption
2 W / 2 VA
Recovery Time (ms)
250
Response Time (ms)
25 (typical)
Supply Voltage
24 V ac/dc +/- 10%
Terminal Type
Screw
Removable Terminals
Yes
Vibration
10-55 Hz at 0.35 mm
Electrical Life (Cycles @ VA)
1,000,000 @ 450 VA
IP Rating
IP20
PL Rating
e
Safety Category Rating
4
SIL Rating
3
SISTEMA
PFHd = 5.1 x 10-10
Safety Input - Single Channel
40-100 mA @ 24 V ac/dc +/- 10%
Input Resistance
100 Ω max. per channel
E-Stops/Rope Pulls
Yes
Safety Mat
No
Motor Speed
No
Muting
No
Gate Switch (NC/NC) Input
Yes
Gate Switch (NC/NO) Input
No
Gate Switch (OSSD) Input
No
Light Curtains/Scanner with EDM Input
No
Light Curtains/Scanner without EDM Input
No
EtherNet/IP
No
Common Ethernet Protocol
No
Modbus/TCP
No
PCCC
No
PROFINET
No
Cascade with ISD
No
Recovery Time
250

Los siguientes productos están incluidos en su pedido.

Archivos CAD

Date
Type
Size
GM-FA/ES-FA
22 Mar 2016
DXF
458K
GM-FA/ES-FA
22 Mar 2016
IGS
2.2MB
GM-FA/ES-FA
22 Mar 2016
PDF
158K
GM-FA/ES-FA
22 Mar 2016
STP
868K

Literatura Técnica

Date
Type
Size
ES-FA-9AA and ES-FA-11AA Safety Modules
12 Aug 2016
DATA SHEET
381K

Certificaciones

Date
Type
Size
DoC for ES-FA-XAA, UM-FA-XA
22 Nov 2019
CERTIFICATION
6MB
ES-FA-11AA
ES-FA-11AA