Especificaciones
- Power
- DC
- IP Rating
- IP20
- EtherCAT
- No
- Network View and Configure
- Yes
- Supply Voltage
- 24 V dc
- Item Status
- RELEASED
- Device Type
- Safety Controller
- In-Series Diagnostics
- No
- Safety Module Type
- Base Controller
- LCD Display
- No
- Expandable
- Yes
- Dimension (H x W x D in mm)
- 110 x 45 x 129
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature (C)
- 55
- Input Operation
- Simultaneous or Concurrent
- Number of Safe Inputs
- 26
- Input Configuration
- Configurable
- Number of Convertible Inputs
- 8
- Safety Input - Dual Channel (Dry Contact)
- 5-50 mA @ 24 V dc
- Safety Input - Dual Channel (Solid-State)
- 50 mA @ 15 - 30 V dc
- Safety Input - Reset
- 5-50 mA @ 24 V dc
- Independently Controlled Safe Outputs
- 4
- Output Configuration
- 2 OSSD Pairs
- Non Safe Output Configuration
- Up to 11 PNP
- Non Safe Output Rating
- 80 mA @ 24 V dc (individual) max for IOx; overcurrent protected, 500 mA @ 24 V dc for Sox
- Safe Output Rating
- OSSD 0.50 A max. @ 24 V dc
- Splittable Safe Output
- Yes
- Power Consumption
- 0.14 A (controller only); 3.6 A (bus load)
- Response Time (ms)
- See Software Configuration Summary
- Terminal Type
- Screw
- Removable Terminals
- Yes
- Vibration
- 9-150 Hz at 1g occasional/0.5g continuous
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 1.05 x 10-9
- THC Rating
- IIIC
- Safety Input - Single Channel
- 5-50 mA @ 24 V dc
- Input Resistance
- 150 Ω max. per lead
- E-Stops/Rope Pulls
- Yes
- Safety Mat
- Yes
- Motor Speed
- No
- Two-Hand Controls
- Yes
- Muting
- Yes
- Gate Switch (NC/NC) Input
- Yes
- Gate Switch (NC/NO) Input
- Yes
- Gate Switch (OSSD) Input
- Yes
- Light Curtains/Scanner with EDM Input
- Yes
- Light Curtains/Scanner without EDM Input
- Yes
- EtherNet/IP
- Yes
- Common Ethernet Protocol
- No
- Modbus/TCP
- Yes
- PCCC
- Yes
- PROFINET
- Yes
- Recovery Time
- 250 (typical), 400 (max)
- EPLAN Status
- Published
- EPLAN Original Sent Date
- 06/20/2022
Descargas
Archivos CAD
Documentación técnica
Fecha
Tipo
Tamaño
Literatura técnica traducida
Lengua
Fecha
Tipo
Tamaño
Certificaciones
Fecha
Tipo
Tamaño
Archivos con Datos del Producto
Fecha
Tipo
Tamaño
Archivos de soporte de PLC
Fecha
Tipo
Tamaño
Software
Fecha
Tipo
Tamaño
EPLAN
Fecha
Tipo
Tamaño
XS26-2E
Detalle del Producto: XS26 Controlador de Seguridad Expandible