LE550UQP

Detalhes do Item Sensores de Deslocamento a Laser com Alcance de 1 m Série LE
LE550UQP
LE550UQP
LE550UQP

Certificações

  • NRKH NRKH7 Vol1 Sec7
  • CE

Amplificadores Compatíveis

Onde aplicável, o alcance máximo para fibras de modo oposto também depende do comprimento da fibra.

Sensing Beam
Visible Red Laser
Power
DC
Cable Length (m)
0.15
PC Configurable
No
Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Triangulation
Housing Style
Rectangular
Device Type
Sensor
Primary Housing Material
Zinc Alloy Die-Cast
Laser Classification
Class 2
Input/Output
Analog & Discrete
Indicator
LCD; LED(s)
Connection
Pigtail QD
Analog Output Configuration
0-10 V dc
Analog Resolution/Discrete Repeatability
100 mm to 600 mm: < 0.5; 600 mm to 1000 mm: < 1
Quick Disconnect Type
M12 (Euro)
Max Sensing Distance (mm)
1000
Minimum Sensing Distance (mm)
100
Sensing Beam
Visible Red Laser
Power Supply
12-30 V dc
Delay at Power-up (ms)
2000
Sensing Beam Wavelength (nm)
650
Adjustments
Push Button; Remote Teach
Temperature Effect (mm/°C)
+/- 0.25 mm/°C from 100 to 600 mm, +/- 0.5 mm/°C at 1000 mm
Number of Pins
5
Vibration
MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage NPN Outputs
< 1.6 V at 100 mA
Output Saturation Voltage PNP Outputs
< 3 V at 100 mA
Analog Voltage Output Rating
2.5 kΩ min. load impedance
Max Discrete (Switched) Output (mA)
100
Discrete (Switched) Outputs
1 NPN/PNP Configurable
Output Protection
Protected against continuous overload and short circuit
IP Rating
IP67
NEMA Rating
NEMA 6
Storage Temperature (°C)
-30 to 65
Max Operating Temperature (°C)
55
Min Operating Temperature (°C)
-20
Max Op. Relative Humidity Non-Condensing (%)
90 at 55°C
Window Material
Acrylic
Warm-up Time (minutes)
10
Minimum Response Time (ms)
2
Spot Size (@ Reference Distance)
4.9 mm x 12.1 mm @ 1 m
Analog Linearity (mm)
Linearity is the lesser of Accuracy or 0.5% of full scale range (± 4.5 mm) at any given distance
Minimum Window Size (mm)
10
Remote Teach and Laser Control Input Impedence
18 kΩ min. (65 kΩ min at 5 V dc)
Discrete Output Hysteresis (mm)
Automatically adjusted
Laser Control
Yes
Alarm Output (mA)
100
Max Ambient Light (Lux)
10000
Max Off-state Leakage Current (µA)
NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
Power/Current Consumption (exclusive of load)
70 mA @ 24 V dc
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Timing (Hold/Delay)
Yes
Feature: Chemical Resistant
No
Feature: Health/ Marginal Signal Output
Yes
Common Ethernet Protocol
No
IO Link
No
PROFINET
No
RS-232
No
RS-422
No
RS-485
No
SSI
No
Wireless
No
1-wire Serial Interface
No
Profibus
No

Os seguintes produtos estão incluídos no seu pedido

Arquivos CAD

Date
Type
Size
L-GAGE LE SERIES CABLE/PIGTAIL
6 Aug 2014
PDF
242K
L-GAGE LE SERIES CABLE/PIGTAIL
6 Aug 2014
DXF
783K
L-GAGE LE SERIES CABLE/PIGTAIL
6 Aug 2014
STP
3.6MB
L-GAGE LE SERIES CABLE/PIGTAIL
6 Aug 2014
IGS
2.3MB

Literatura Técnica

Date
Type
Size
L-GAGE LE250/550 Analog/Discrete Laser Gauging Sensors -- Instruction Manual
23 Jan 2018
PRODUCT MANUAL
1.4MB
L-GAGE LE250/550 Analog/Discrete Laser Gauging Sensors -- Quick Start Guide
6 Nov 2015
QUICK START GUIDE
832K

Certificações

Date
Type
Size
DoC  for LE Series
10 Jul 2018
CERTIFICATION
6MB
  • Wiring Diagram

    Product Technical Diagram
  • Pin Out

    Product Technical Diagram
  • Tech Diagrams

    Product Technical Diagram
  • Tech Diagrams

    Product Technical Diagram
LE550UQP
LE550UQP
Detalhes do Item: Sensores de Deslocamento a Laser com Alcance de 1 m Série LE

Certificações

  • NRKH NRKH7 Vol1 Sec7
  • CE