SGS Series

Safety Grid System

SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications. They are available in Emitter/Receiver models capable of safeguarding over very long distances and in easy-to-deploy Active/Passive models that offer additional cost savings.

  • Models available with integral muting for entry/exit conveyors or palletizing cells
  • Heavy-duty aluminum housing for tough environments
  • Easy alignment and installation with on-board alignment lamp and indicators
  • Protective defined area heights of 500, 800, 900, or 1200 mm available
  • Up to 60 meter range available for perimeter guarding applications
  • Muting arm kits available to simplify end-of-line packaging applications

Technical Literature

Date
Type
Size
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual
5 Sep 2019
Product Manual
14.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual
7 Jun 2019
Product Manual
6MB
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual
18 Dec 2018
Product Manual
3.9MB
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting
27 Apr 2018
Datasheet
601K
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual
25 Jan 2018
Product Manual
2.3MB
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models)
16 Jan 2018
Checkout Procedure
92K
SGS Safety Grid System Daily Checkout Procedure (Muting Models)
16 Jan 2018
Checkout Procedure
121K
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models)
16 Jan 2018
Checkout Procedure
121K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models)
16 Jan 2018
Checkout Procedure
88K
SGS Safety Grid System -- Datasheet
3 Nov 2017
Datasheet
109K
SGSA-MCB Safety Grid System Connection Box
22 Sep 2017
Datasheet
460K
Date
Type
Size
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (French)
01/04/19
Product Manual
14.7MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (French)
01/04/19
Product Manual
5.5MB
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (French)
01/04/19
Checkout Procedure
82K
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (French)
01/04/19
Checkout Procedure
115K
SGS Safety Grid System (Emitter/Receiver) -- Instruction Manual (French)
01/04/19
Product Manual
4.6MB
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (French)
01/04/19
Product Manual
13.7MB
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (French)
08/06/18
Datasheet
583K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (French)
08/06/18
Checkout Procedure
115K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (French)
08/06/18
Checkout Procedure
86K
Date
Type
Size
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (German)
01/04/19
Product Manual
14.4MB
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (German)
01/04/19
Product Manual
13.5MB
SGS Safety Grid System (ActivePassive) -- Instruction Manual (German)
01/04/19
Product Manual
5.5MB
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (German)
01/04/19
Checkout Procedure
108K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (German)
01/04/19
Checkout Procedure
75K
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (German)
01/04/19
Product Manual
4.6MB
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (German)
08/06/18
Datasheet
582K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (German)
SGS Sicherheitsgittersystem
08/06/18
Checkout Procedure
108K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (German)
SGS Sicherheitsgittersystem
08/06/18
Checkout Procedure
78K
Date
Type
Size
SGS Safety Grid System (Active/Passive with Integral Muting) - Instruction Manual (Italian)
01/04/19
Product Manual
14.4MB
SGS Safety Grid System (Emitter/Receiver with Integral Muting) -- Instruction Manual (Italian)
01/04/19
Product Manual
13.5MB
SGS Safety Grid System Daily Checkout Procedure (Non-Muting Models) (Italian)
01/04/19
Checkout Procedure
114K
SGS Safety Grid System Semi-Annual Checkout Procedure (Non-Muting Models) (Italian)
01/04/19
Checkout Procedure
82K
SGS Safety Grid System (ActivePassive) -- Instruction Manual (Italian)
01/04/19
Product Manual
5.5MB
SGS Safety Grid System (EmitterReceiver) -- Instruction Manual (Italian)
01/04/19
Product Manual
4.6MB
SGSA-LXT Muting Arm Sensor Kits for SGS Safety Grid Systems with Integral Muting (Italian)
08/06/18
Datasheet
581K
SGS Safety Grid System Daily Checkout Procedure (Muting Models) (Italian)
08/06/18
Checkout Procedure
115K
SGS Safety Grid System Semi-Annual Checkout Procedure (Muting Models) (Italian)
08/06/18
Checkout Procedure
83K

Marketing Literature

Date
Type
Size
SGS Safety Grids Sell Sheet
18 Mar 2019
Product Brochure
1.8MB
Date
Type
Size
SGS Safety Grids Sell Sheet
SGS 安全光栅系统
10/25/18
Product Brochure
2.4MB
Area and Gate Guarding on Automotive Assembly Line
Area and Gate Guarding on Automotive Assembly Line

A car travels along a conveyor into a hazardous area guarded by an SGS Series Safety Grid System. As the car approaches, the SGS Grid is temporarily muted to allow the car to pass without stopping the conveyor. While the Grid is muted, there is the risk that a worker will attempt to enter the hazardous area through the interlocked breakaway guard, putting the worker in a dangerous situation and presenting the possibility that the worker will be struck by the moving car.

Perimeter Guarding on a Tube Bending Machine
Perimeter Guarding on a Tube Bending Machine

Widely spaced SGS safety grid platform light screen economically protects the perimeter of a work area. The grid is far enough from the hazard that motion has time to stop if a person or object passes through the grid.

Guarding Conveyor Entry on Palletizer Machines
Guarding Conveyor Entry on Palletizer Machines

Safeguarding palletizer machines present many challenges to keep personnel safe and maintain efficient production. The new SGS Safety Grid with muting arm bar kit protects the dangerous robotic machinery while allowing boxes to pass through the Grids without stopping production. The muting arms can recognize if anything other than a box passes through the Grids and will trigger a machine stop on the palletizer.

SGS - Safety Grid System [Video]
SGS - Safety Grid System

SGS Safety Grid Systems are cost-effective multiple beam safety light devices for access and long-range perimeter guarding applications.

Product Selection

Loading...

Narrow Results

clear all filters

Defined Area Height (mm)

  • (6)
  • (6)
  • (6)
  • (6)

Operating Distance (m)

  • (8)
  • (3)
  • (9)
  • (4)

Integral Muting

  • (12)
  • (12)

System Type

  • (12)
  • (4)
  • (8)

Resolution (mm)

  • (6)
  • (6)
  • (6)
  • (6)
View All View Less
selected filters
  1. SGSXP2-500Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 6 to 60 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  2. SGSMA3-400Q12

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 8 m
    Connection: M12 12-pin QD; M12 5-pin QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  3. SGSSP4-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  4. SGSXP3-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 6 to 60 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  5. SGSB4-400

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 8 m
    Mounting Hardware Ordered Separately

  6. SGSSA4-400Q8

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 8 m
    Connection: M12 8-pin QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  7. SGSB3-400

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 8 m
    Mounting Hardware Ordered Separately

  8. SGSSP4-300Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  9. SGSB2-500

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 8 m
    Mounting Hardware Ordered Separately

  10. SGSSP3-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  11. SGSB4-300

    logo with r symbol

    Safety Grid, Passive Mirror Assembly
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    Mounting Hardware Ordered Separately

  12. SGSSA2-500Q8

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 8 m
    Connection: M12 8-pin QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  13. SGSXP4-300Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 6 to 60 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  14. SGSXP4-400Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 6 to 60 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  15. SGSMA4-400Q12

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 8 m
    Connection: M12 12-pin QD; M12 5-pin QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  16. SGSMP4-300Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 30 m
    Connection: M12 12-pin QD (R), 8-pin (E); M12 5-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  17. SGSMP4-400Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 4; Resolution: 400 mm; Range: 0.5 to 30 m
    Connection: M12 12-pin QD (R), 8-pin (E); M12 5-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  18. SGSSA4-300Q8

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    Connection: M12 8-pin QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  19. SGSMA4-300Q12

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 4; Resolution: 300 mm; Range: 0.5 to 6.5 m
    Connection: M12 12-pin QD; M12 5-pin QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  20. SGSMP3-400Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 30 m
    Connection: M12 12-pin QD (R), 8-pin (E); M12 5-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  21. SGSSA3-400Q8

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 3; Resolution: 400 mm; Range: 0.5 to 8 m
    Connection: M12 8-pin QD
    Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  22. SGSSP2-500Q88

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
    Connection: M12 8-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM
    Mounting Hardware Ordered Separately

  23. SGSMA2-500Q12

    logo with r symbol

    SGS Safety Grid System, Active Tranceiver
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 8 m
    Connection: M12 12-pin QD; M12 5-pin QD
    Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately

  24. SGSMP2-500Q128

    logo with r symbol

    SGS Safety Grid System, Emitter/Receiver Pair
    Beams: 2; Resolution: 500 mm; Range: 0.5 to 30 m
    Connection: M12 12-pin QD (R), 8-pin (E); M12 5-pin QD
    Scan Codes, Auto/Manual Start/Restart, EDM, Integral Muting
    Mounting Hardware Ordered Separately