• Voltar

  • Eight-Port Hub Device for IO-Link Connections

    R95C IO-Link Hub

    R95C Series IO-Link Hubs allow control and monitoring of discrete and/or analog signals by an IO-Link Master, allowing I/O to be located closer to devices, which reduces wiring complexity and time. I/O types vary depending on model, and include PNP, NPN, 4–20 mA, and 0–10 V DC.

    • Simplify I/O configuration and reduce SKUs
      • Analog ports can be independently configured as current or voltage
      • Discrete ports can be independently configured as PNP or NPN
    • Reduce programming at the PLC as well as communication latency between devices
      • Port mirroring feature allows for analog or discrete inputs to be mapped to one or more outputs on the same device
      • Discrete hubs feature delay modes including on/off delays and one-shots
    • Improve cable routing and increase installation options
      • Stackable design allows for multiple units to be mounted in an area with a smaller footprint
      • Cable bend-radius issues can be resolved due to unique side-exit port design
      • Rugged over-molded design meets IP65, IP66 and IP67 and offers more flexibility in machine mounting location
    OPTIMIZE CONTROL SYSTEM PERFORMANCE
    Remote I/O

    Downloads

    Literatura Técnica

    Data
    Tipo
    Tamanho
    R95C 8-Port 2-Channel Discrete and Analog In-Out IO-Link Data Reference Guide
    19 Mar 2024
    Manual do Produto
    961K
    R95C 8-Port Analog In to IO-Link Hub Instruction Manual
    2 Nov 2023
    Manual do Produto
    9.5MB
    R95C 8-Port Analog In to IO-Link Hub Quick Start Guide
    2 Nov 2023
    Guia Quickstart
    890K
    R95C 8-Port Analog In to IO-Link Hub IO Link Data Reference Guide
    14 Aug 2023
    Manual do Produto
    840K
    R95C 8-Port 2-Channel Discrete Bimodal IO-Link-Hub Instruction Manual
    13 Mar 2023
    Manual do Produto
    7.4MB
    R95C 8-Port Discrete Bimodal to IO-Link Hub Instruction Manual
    15 Dec 2022
    Manual do Produto
    2.2MB
    Data
    Tipo
    Tamanho
    R95C 8-Port Discrete Bimodal to IO-Link Hub Instruction Manual (French)
    10/20/22
    Manual do Produto
    2.3MB
    Data
    Tipo
    Tamanho
    R95C 8-Port Discrete Bimodal to IO-Link Hub Instruction Manual (German)
    11/04/22
    Manual do Produto
    2.3MB
    Data
    Tipo
    Tamanho
    R95C 8-Port Discrete Bimodal to IO-Link Hub Instruction Manual (Italian)
    10/31/22
    Manual do Produto
    2.3MB

    Arquivo de Dados do Produto

    Data
    Tipo
    Tamanho
    R95C-8B21-KQ IODD Files
    13 Sep 2022
    Arquivos IODD
    3.1MB

    PLC Support Files

    Data
    Tipo
    Tamanho
    R95C 8UI Hub AOIs
    13 Aug 2024
    AOI
    5.5MB
    R90C R95C R130C B21 B22 Hub AOIs
    13 Aug 2024
    AOI
    6.1MB
    R90C R95C R130C Hub AOI Files
    13 Aug 2024
    AOI
    6.1MB
    R95C 4B4UI Hub AOIs
    13 Aug 2024
    AOI
    5.3MB

    Literatura de Marketing

    Data
    Tipo
    Tamanho
    Snap Signal Brochure
    Snap Signal Brochure
    14 Nov 2024
    Folhetos de Produtos
    6MB
    Remote IO Brochure
    Remote IO Brochure
    11 Sep 2024
    Folhetos de Produtos
    2.2MB
    IO-Link Solutions Brochure
    IO-Link Solutions Brochure
    11 Sep 2024
    Folhetos de Produtos
    4.9MB
    R95C IO-Link Hub Sell Sheet
    R95C IO-Link Hub Sell Sheet
    30 Sep 2022
    Folhetos de Produtos
    320K
    • How-To: R95C IO-Link Hub One Shot Timing Logic

      How-To: R95C IO-Link Hub One Shot Timing Logic

      This video demonstrates how to set up one shot timing logic with the R95C Hybrid IO-Link Hub from Banner Engineering.

    • How-To: R95C IO-Link Hub Analog-to-PFM Conversion

      How-To: R95C IO-Link Hub Analog-to-PFM Conversion

      This video demonstrates how to set up port mirroring with an analog-to-PFM conversion using the R95C Hybrid IO-Link Hub.

    • How-To: R95C IO-Link Hub Port Mirroring

      How-To: R95C IO-Link Hub Port Mirroring

      This video demonstrates how to set up simple port mirroring with the R95C Hybrid IO-Link Hub from Banner Engineering.

    • How To: R95C IO-Link Hub Analog Port Mirroring

      How To: R95C IO-Link Hub Analog Port Mirroring

      This video demonstrates how to set up analog port mirroring with R95C Hybrid IO-Link Hub from Banner Engineering.

    • How-To: R95C IO-Link Hub On-Off Delay

      How-To: R95C IO-Link Hub On-Off Delay

      This video demonstrates how to set up On and Off delays with the R95C Hybrid IO-Link Hub from Banner Engineering.

    Product Selection

    Carregando...

    Filtrar Resultados

    limpar todos os filtros

    Entrada

    • (1)
    • (3)

    Input 2

    • (1)
    • (1)
    Exibir Tudo Exibir Menos
    filtros selecionados
    1. R95C-8UI-KQ

      logo with r symbol

      R95C Series: 8 port Analog IO-link Hub
      IO-link Interface
      4-pin M12 QDs

    2. R95C-4B4UI-KQ

      logo with r symbol

      R95C Series: 8 port Hybrid IO-Link Hub
      4 Analog Inputs and 4 Analog Outputs and 8 Discrete Inputs or 8 Discrete Outputs (Configurable)
      IO-Link Interface
      4-pin M12 QDs

    3. R95C-8B21-KQ

      logo with r symbol

      R95C Series: 8 port Discrete IO-link Hub
      16 Inputs or 8 Inputs/8 Outputs (Configurable)
      IO-link Interface
      4-pin M12 QDs

    4. R95C-8B22-KQ

      logo with r symbol

      R95C Series: 8 port Discrete IO-link Hub
      16 Inputs or 16 Outputs (Configurable)
      IO-link Interface
      4-pin M12 QDs

    Adicionar à Minha Biblioteca
    Adicionado