Independent Coverage and Control Across Conveyor Lines
Use RSio’s In-Series Diagnostics (ISD) capabilities to create individual safety zones on long-run conveyors common in distribution, 3PL, and material-handling environments. On one safety input, an ISD chain consisting of a rope pull brought in via ISD Connect and a series of e-stops provides stop coverage along the first conveyor line. A second safety input brings in another ISD chain of e-stops to protect a second line. A final switching device (FSD) connected to one of RSio’s safety-rated outputs controls the motor-driven rollers on the first line, while the second line’s final switching device is controlled by the safety controller via the CIP Safety connection. A hybrid port configured as a standard output drives a CL50 Column Light to provide system-status indication at a distance.
When any device in the first ISD chain is tripped, RSio drops the safety output to remove power from the FSD and stop the first conveyor. When a device in the second ISD chain is tripped, RSio reports the safety input status to the Safety PLC over the CIP Safety connection on the EtherNet/IP network, and the Safety PLC commands its final switching device to stop the second conveyor. ISD device-level diagnostics help maintenance quickly locate which device along either line needs attention.
Featured Products
-
RSio Remote Safe I/O
Banner RSio remote safe I/O integrates ISD diagnostics into CIP Safety systems with PLe/SIL3 capability and Studio 5000 configuration via included EDS
-
具有緊急停止按鈕的安全拉繩開關
當拉繩緊急停止開關與鋼索一起使用時,輸送帶和大型機械將會提供緊急停止啟動功能。
-
30mm 孔位安裝緊急停止按鈕
發光按鈕,便於識別已致動的緊急停止裝置。30mm孔位安裝底座,便於安裝和連接,無需組裝。
-
CL50 Series 50 mm LED Column Lights
大型、一體式IP67等級指示燈,使用耐用的LED燈源,在單個燈層中提供可見度很高的多色指示燈。