PVA系列
PVA系列一體型零件拾取檢查感測器
- 提供4種長度,以適應現有 零部件箱的多種尺寸和設定
- 工作距離可達2 m(6.5英呎)
- 雙組件系統(發射端和接收端),不需要同步線或控制器盒 。
- 明顯易見的綠色指示燈安裝在發射端或接收端外殼;可以遠端控制指示燈,在 持續亮或閃爍條件下啟動 使用者動作
- 兩種頻率設定,以防止近距離或多組感測器安裝中的相互干擾
- 可提供重型防護支架
下載
軟體
行銷資料
-
PVA100P6EQ
PVA Series: 100 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m M12 Pigtail QD -
PVA100P6RQ
PVA Series: 100 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
M12 Pigtail QD -
PVA100P6Q
PVA Series: 100 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
M12 Pigtail QD -
PVA225P6RQ
PVA Series: 225 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
M12 Pigtail QD -
PVA225P6EQ
PVA Series: 225 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
M12 Pigtail QD -
PVA225P6Q
PVA Series: 225 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
M12 Pigtail QD -
PVA100P6R
PVA Series: 100 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA100P6
PVA Series: 100 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
2 m (6.5 ft) Integral Cables -
PVA100P6E
PVA Series: 100 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cables -
PVA375P6EQ
NOPVA Series: 375 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
M12 Integral QD -
PVA375P6RQ
PVA Series: 375 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
M12 Pigtail QD -
PVA100N6
PVA Series: 100 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN (on receiver)
2 m (6.5 ft) Integral Cables -
PVA100P6EQ W/6IN
PVA Series: 100 mm Array
Emitter ; Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
150 mm (6 in) M12 Pigtail QD -
PVA100P6RQ W/6IN
PVA Series: 100 mm Array
Receiver; Range: 2 m; Input: 12-30 V dc
Output: 1 PNP
150 mm (6 in) M12 Pigtail QD -
PVA300P6EQ
PVA Series: 300 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
M12 Pigtail QD -
PVA300P6Q
PVA Series: 300 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
2 m M12 Pigtail QD -
PVA300P6R
PVA Series: 300 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA375P6Q
PVA Series: 375 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
2 m M12 Pigtail QD -
PVA100N6E
PVA Series: 100 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cables -
PVA100N6EQ
PVA Series: 100 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
M12 Integral QD -
PVA100N6Q
PVA Series: 100 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN (on receiver)
M12 Integral QD -
PVA100N6R
PVA Series: 100 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA100N6RQ
PVA Series: 100 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
M12 Pigtail QD -
PVA225N6
PVA Series: 225 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN (on receiver)
2 m (6.5 ft) Integral Cables -
PVA225N6E
PVA Series: 225 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cable -
PVA225N6R
PVA Series: 225 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA225P6
PVA Series: 225 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
2 m (6.5 ft) Integral Cables -
PVA225P6E
PVA Series: 225 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cable -
PVA225P6QK
PVA Series: 225 mm Array
E/R and bracket kit; Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
M12 2 m Pigtail QD -
PVA225P6R
PVA Series: 225 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA300N6
PVA Series: 300 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN (on receiver)
2 m (6.5 ft) Integral Cables -
PVA300N6E
PVA Series: 300 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cable -
PVA300N6EQ
PVA Series: 300 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
M12 Pigtail QD -
PVA300N6R
PVA Series: 300 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA300N6RQ
PVA Series: 300 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
M12 Pigtail QD -
PVA300P6
PVA Series: 300 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
2 m (6.5 ft) Integral Cables -
PVA300P6E
PVA Series: 300 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cable -
PVA300P6RQ
PVA Series: 300 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
M12 Pigtail QD -
PVA375N6
PVA Series: 375 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN (on receiver)
2 m (6.5 ft) Integral Cables -
PVA375N6E
PVA Series: 375 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cable -
PVA375N6EQ
PVA Series: 375 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
M12 Pigtail QD -
PVA375N6Q
PVA Series: 375 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN (on receiver)
M12 Pigtail QD -
PVA375N6R
PVA Series: 375 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
2 m (6.5 ft) Integral Cable -
PVA375N6RQ
PVA Series: 375 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 NPN Programmable for LO/DO
M12 Pigtail QD -
PVA375P6
PVA Series: 375 mm Array Pair - Emitter/Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP (on receiver)
2 m (6.5 ft) Integral Cables -
PVA375P6E
PVA Series: 375 mm Array - Emitter
Range: 2 m; Input: 12-30 V dc
Output: Not Applicable
2 m (6.5 ft) Integral Cable -
PVA375P6R
PVA Series: 375 mm Array - Receiver
Range: 2 m; Input: 12-30 V dc
Output: 1 PNP Programmable for LO/DO
2 m (6.5 ft) Integral Cable