ES-FA-11AA
Certificações
Amplificadores Compatíveis
Onde aplicável, o alcance máximo para fibras de modo oposto também depende do comprimento da fibra.
Especificações
- Power
- AC/DC Universal
- IP Rating
- IP20
- Device Type
- Safety Relay
- In-Series Diagnostics
- No
- Safety Module Type
- Emergency Stop Module
- Expandable
- No
- LCD Display
- No
- Dimension (H x W x D in mm)
- 84 x 22.5 x 118
- Relative Humidity
- 90% @ 50° C
- Max Operating Temperature ( °C)
- 50
- Input Operation
- Simultaneous or Concurrent
- Number of Safe Inputs
- 1
- Input Configuration
- 2 NC or 1 NC
- Safety Input - Dual Channel (Dry Contact)
- 10-20 mA @ 12 V dc
- Safety Input - Reset
- 20 mA @ 12 V dc (dry contact only)
- Independently Controlled Safe Outputs
- 1
- Output Configuration
- 2 NO
- Non Safe Output Configuration
- 1 NC
- Non Safe Output Rating
- Relay - 7 A
- Safe Output Rating
- Relay - 7 A
- Splittable Safe Output
- No
- Mechanical Life (Operations in Millions)
- 20
- Power Consumption
- 2 W / 2 VA
- Recovery Time (ms)
- 250
- Response Time (ms)
- 25 (typical)
- Supply Voltage
- 24 V ac/dc +/- 10%
- Terminal Type
- Screw
- Removable Terminals
- Yes
- Vibration
- 10-55 Hz at 0.35 mm
- Electrical Life (Cycles @ VA)
- 1,000,000 @ 450 VA
- PL Rating
- e
- Safety Category Rating
- 4
- SIL Rating
- 3
- SISTEMA
- PFHd = 5.1 x 10-10
- Safety Input - Single Channel
- 40-100 mA @ 24 V ac/dc +/- 10%
- Input Resistance
- 100 Ω max. per channel
- E-Stops/Rope Pulls
- Yes
- Safety Mat
- No
- Motor Speed
- No
- Muting
- No
- Gate Switch (NC/NC) Input
- Yes
- Gate Switch (NC/NO) Input
- No
- Gate Switch (OSSD) Input
- No
- Light Curtains/Scanner with EDM Input
- No
- Light Curtains/Scanner without EDM Input
- No
- Recovery Time
- 250