Snap Signal Configuration Software
Banner Snap Signal configuration software enables the field configuration and demo of Banner Modbus devices
New Products | news
Success Story | news
Success Story | news
Success Story | news
New Products | news
New Products | news
New Products | news
New Products | news
New Products | news
New Products | news
New Products | news
Success Story | DXM
Success Story | Wireless Solutions
Success Story | Wireless Gateways and Nodes
Success Story | QS18
Success Story | R58
Success Story | Smart Sensors
Success Story | CL50
Success Story | IVU
Success Story | IVU
Success Story | PTL110
Success Story | PTL110
Success Story | PTL Products
Success Story | news
Success Story | news
Success Story | K50L
Success Story
Success Story | K50FL
Success Story | LE
Success Story
Success Story | WLA
Success Story | Lentes
Success Story | T30R
Success Story | QT50R
Success Story | Node Sem Fio M-GAGE
Welcome to a short how-to video that will cover the basics of the Snap Signal configuration software from Banner Engineering.
To begin, connect a compatible Modbus sensor or S15C converter to a Windows PC, using the RS485 to USB adapter cable, and by following the diagram in the manual.
The manual can be found by navigating to the 'Help' menu and clicking on 'Documentation'.
In this example, we will be connecting an S15S-T-MQ temperature sensor.
Click 'Connect', and then select the comm port to which the device is connected.
If you're not sure which port to select, disconnect the USB cable and hit the 'Refresh' icon; the comm port that disappears is the one you will need to select.
Click 'Find' to load the sensor's information and click 'Submit'.
The device configuration section is where you can choose basic communication settings.
The most important field is the SID, or server ID.
A unique SID must be set for each device that will be in a server chain, and it can be set to any value between 1 and 247.
You can also choose a custom user tag, which allows you to label the device with identifying information such as the product type, location, or any other helpful information.
When you're finished configuring the device information, click 'Write' to save the settings.
The 'Live Demo' section allows you to pull real time measurement data from the device.
Select the data parameter you wish to pull from the dropdown menu and click 'Start Polling'.
The graph will continually update with the data in real time until you click 'Stop Polling'.
The 'All Signals' section provides momentary values of all available measurement registers, as well as any internal data provided by the device, such as internal temperatures.
To update the signal values, click the 'Read' icon.
That covers the basics of the Snap Signal configuration software.
For more information, visit bannerengineering.com.
Application solutions, new product updates, answers to frequently asked questions, and more delivered 1-2 times a month.