DXM Series industrial wireless controllers are designed to facilitate Ethernet connectivity and Industrial Internet of Things (IIoT) applications. Available with an internal DX80 Gateway or a MultiHop Data Radio, these powerful Modbus communications devices connect local wireless networks with the internet and/or host systems.
Additional Technical Notes available in the Wireless Reference Library.
Wireless monitoring of rotating parts on coal conveyors throughout a large port allows operators to utilize predictive maintenance to prevent failure and save money while reducing downtime.
Wireless products enable predictive maintenance in the port industry. Motors and gearboxes on cranes are prone to high vibration and temperature which can cause them to degrade. Predictive maintenance allows employees to interfere and solve problems before they completely fail and cause unplanned downtime and lost profit.
Learn how the installation of Banner wireless vibration sensors and data from the DXM wireless gateway prevented unplanned downtime in this application.
IIoT solutions from Banner Engineering provide companies with greater visibility into their operations by enabling access to critical performance and production data, making it easy to solve problems, identify trends, and make better, data driven decisions.
Calculating Overall Equipment Effectiveness (OEE) can help you improve efficiency and productivity. With a wireless system, you can track uptime, validate throughput, monitor quality, and optimize your operation.
Monitor machine health utilizing predictive maintenance by continuously monitoring for vibration and temperature changes.
Wireless vehicle detection at a quick serve restaurant drive-thru ensures speed of service and efficiency.
Creating a safe environment for customers and staff is essential for retail establishments. Wireless technology can be used to support social distancing initiatives by making it easy to monitor and control the number of customers inside a store.
Banner Engineering offers a simple, flexible, and effective solution for an office area cleaning program. Operators work as normal and receive an indication when it is time to clean the space.
Banner’s occupancy monitoring solution automates the monitoring of entrances and exits and provides easy-to-understand visual indication to customers when they can enter the store.
Learn how to improve communication and maintain a steady workflow with Banner Engineering's wireless call for parts solution.
Monitor machine health utilizing predictive maintenance by continuously monitoring for vibration and temperature changes.
Standard Features | DXM1200-B1 | DXM1000-B1 | DXM700-B1 | DXM100-Bx | DXM150-B2 | DXM150-B1 |
Performance or MultiHop Radio option | ✓ | ✓ | ✓    | ✓ | ✓ | ✓ |
900 MHz or 2.4 GHz ISM Radio option | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Cellular communications option | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
LCD User Interface and 4 LEDs | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
8GB Removable Micro SD Card | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Environmental Rating | IP67 | IP20 | IP20 | IP20 | IP20 | IP20 |
Battery backup option |  | ✓ |  | ✓ | ✓ | ✓ |
Solar power option |  | ✓ |  | ✓ | ✓ | ✓ |
Modbus/TCP and Ethernet/IP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Modbus RTU RS-485 | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
RS-232 |  | ✓ |  | ✓ | ✓ | ✓ |
CANBus |  | ✓ |  | ✓ | ✓ | ✓ |
USB and Ethernet Configuration | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
Logic Controller (Action rule or ScriptBasic programmable) | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |
SMS Capability |  |  |  | ✓ | ✓ | ✓ |
Slave Option (IO Board and Radio Only) |  |  |  | ✓ | ✓ | ✓ |
Processor Speed and Memory | 300 MHz, 16 MB | 300 MHz, 16 MB | 300 MHz, 16 MB | 100 MHz, 2 MB | 100 MHz, 2 MB | 100 MHz, 2 MB |
Sinking (NPN)/Sourcing (PNP) Outputs | Â | Â | 4 PNP | Â | 8 | Â |
Sinking (NMOS) Outputs (up to 30 V DC at <1 A max) | Â | 4 | Â | 4 | Â | 4 |
Analog Outputs (0–20 mA or 0–10 V dc, 12-bit resolution) |  | 2 |  | 2 | 2 | 2 |
Relay Outputs (SPDT Form C - 250 V ac 16 A) | Â | Â | Â | Â | Â | 2 |
Universal Inputs (NPN, PNP, 0–20mA, 0–10 V, 10K Thermistor, Potentiometer, NPN Raw Fast) |
 | 4 |  | 4 | 8 | 8 |
Optically Isolated Discrete Inputs (30 V ac or V dc up to 2.5 kV isolation) | Â | Â | Â | Â | 2 | 2 |
Courtesy Power Out | Â | 1 (5 V, 500 mA max) | Â | 1 (5 V, 500 mA max)Â Â Â Â | 4 (2.7 V up to device power |
2 (2.7 V up to device power)Â |
Switched Power Out |  | 2 (5 V, 400 mA max or 16 V, 125 m |  | 2 (5 V, 400 mA max  |
 |  |
DIN Rail Width | Â | 105 mm | 70 mm | 105 mm | 155 mm | 155 mm |
DXM700 controller with M7 processor, 16MB memory
LCD display, 4 sourcing outputs, Ethernet, USB
CAN, 900MHz Performance 1W Gateway
DXM700 controller with M7 processor, 16MB memory
LCD display, 4 sourcing outputs, Ethernet, USB
CAN, 2.4GHz Performance Gateway
DXM700 controller with M7 processor, 16MB memory
LCD display, 4 sourcing outputs, Ethernet, USB
CAN, 900MHz MultiHop 1W Master
DXM100 Controller
DX80 Performance 900 MHz Radio 1W
Inputs: 4 Universal
Outputs: 4 NMOS Discrete, 2 Selectable Analog, 2 Switched Power, 1 Courtesy Power
SAM4 Processor, LCD Display