  • How To Set Up Muting with the LS Safety Light Curtain

    Learn how to set-up the XS safety controller to work with a mute arm kit and LS safety light curtain. Banner’s pre-assembled mute arm kits are available in L, T and X configurations as a plug-n-play solution for end of line packaging applications.

    Learn More About iVu Series Vision Sensors

    LS 시리즈 튜브형 인클로저 헤비 듀티 타입 4 안전 라이트 커튼
    LS 시리즈 튜브형 인클로저 헤비 듀티 타입 4

    사각 지대 없는 완벽한 기능으로 설계되어 직관적이고 사용하기 쉬우며 기능이 풍부한 23 mm 분해능도 선택 가능한 모델. 70 mm IP69의 위생적인 튜브형 인클로저에 응축을 방지하는 소수성 통기구를 갖춘 모델로 정의 영역 높이를 280 ~ 1050 mm 사이 7가지 중에서 선택 가능합니다.

    Read More

    Transcript

    Banner’s pre-assembled Mute Arm Kits are available in L, T and X configurations as a plug-n-play solution for end of line packaging applications.

    You can now use these mute arm kits with Banner EZ SCREEN LS Safety Light Curtains through the use of the XS safety controller.

    Banner offers accessories to make mounting and electrical connection a breeze.

    In this video will show you how to set-up the XS safety controller to work with the Mute Arm Kits, it’s really simple…

    Add a safety light curtain

    Add a mute sensor pair

    The only trick here is you have to select Dual-Chanel PNP

    In the functional View tab to create the configuration

    Add a muting function block

    If you have an L-Configuration use the one on the top left (maybe add a visual showing L, T and X configurations)

    If you have a T or X Configuration use the one on the top right

    There are a few advanced features as well

    Mute enable

    Mute time limit

    And End Delay Time limit can be set for L-configurations

    Add a latch reset function block and a latch reset

    Use a physical manual reset button or use the virtual reset from an HMI.

    Add a status output for the mute light.

    In simulation mode we will test the configuration

    First we test the safety light curtain and latch reset with mute off.

    Next, lets test the mute function.

    When enabled, a function block is purple with a 3 second count-down timer. Also, the status output for the mute light changes to green

    After 3 seconds the status output and mute function turn off.

    Try again an ensure the safety light curtain is muted…success!

    The wiring diagram describes the wiring connections

    Finally, select your industrial ethernet protocol, auto configure and the controller is now set-up up to talk to the PLC.

    Visit bannerengineering.com to view the plug-n-play accessories to complete this set-up.Banner’s pre-assembled Mute Arm Kits are available in L, T and X configurations as a plug-n-play solution for end of line packaging applications.

    You can now use these mute arm kits with Banner EZ SCREEN LS Safety Light Curtains through the use of the XS safety controller.

    Banner offers accessories to make mounting and electrical connection a breeze.

    In this video will show you how to set-up the XS safety controller to work with the Mute Arm Kits, it’s really simple…

    Add a safety light curtain

    Add a mute sensor pair

    The only trick here is you have to select Dual-Chanel PNP

    In the functional View tab to create the configuration

    Add a muting function block

    If you have an L-Configuration use the one on the top left (maybe add a visual showing L, T and X configurations)

    If you have a T or X Configuration use the one on the top right

    There are a few advanced features as well

    Mute enable

    Mute time limit

    And End Delay Time limit can be set for L-configurations

    Add a latch reset function block and a latch reset

    Use a physical manual reset button or use the virtual reset from an HMI.

    Add a status output for the mute light.

    In simulation mode we will test the configuration

    First we test the safety light curtain and latch reset with mute off.

    Next, lets test the mute function.

    When enabled, a function block is purple with a 3 second count-down timer. Also, the status output for the mute light changes to green

    After 3 seconds the status output and mute function turn off.

    Try again an ensure the safety light curtain is muted…success!

    The wiring diagram describes the wiring connections

    Finally, select your industrial ethernet protocol, auto configure and the controller is now set-up up to talk to the PLC.

    Visit bannerengineering.com to view the plug-n-play accessories to complete this set-up.