- Provides a reliable error-proofing system for assembly operations
- Indicates to an assembler which items to pick for a given operation, and the order in which to pick them
- Uses asynchronous emitter and receiver and requires no controller
- Offers 12 to 30V dc supply voltage with either NPN or PNP output
- Provides DIP-switch adjustment of light/dark operate, solid/flashing job light indicator, A/B frequency and gate polarity for activating job light
- Offered in four lengths—100 mm, 225 mm, 300 mm, 375 mm—to fit common bin sizes
- Accommodates 2 meter separation distance
- Incorporates highly visible indicator LEDs
Downloads
Technical Literature
Brochures & Catalogs
- 
                            
    
    
    PVA100P6RQ  PVA Series: 100 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 M12 Pigtail QD
- 
                            
    
    
    PVA100P6EQ  PVA Series: 100 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m M12 Pigtail QD
- 
                            
    
    
    PVA100P6Q  PVA Series: 100 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 M12 Pigtail QD
- 
                            
    
    
    PVA225P6EQ  PVA Series: 225 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 M12 Pigtail QD
- 
                            
    
    
    PVA225P6RQ  PVA Series: 225 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 M12 Pigtail QD
- 
                            
    
    
    PVA225P6Q  PVA Series: 225 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 M12 Pigtail QD
- 
                            
    
    
    PVA100P6  PVA Series: 100 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA100P6E  PVA Series: 100 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA100P6R  PVA Series: 100 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA375P6RQ  PVA Series: 375 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 M12 Pigtail QD
- 
                            
    
    
    PVA100N6RQ  PVA Series: 100 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN Programmable for LO/DO
 M12 Pigtail QD
- 
                            
    
    
    PVA300P6EQ  PVA Series: 300 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 M12 Pigtail QD
- 
                            
    
    
    PVA300P6Q  PVA Series: 300 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 2 m M12 Pigtail QD
- 
                            
    
    
    PVA300P6RQ  PVA Series: 300 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 M12 Pigtail QD
- 
                            
    
    
    PVA100N6EQ  PVA Series: 100 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 M12 Integral QD
- 
                            
    
    
    PVA100N6Q  PVA Series: 100 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN (on receiver)
 M12 Integral QD
- 
                            
    
    
    PVA225N6R  PVA Series: 225 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN Programmable for LO/DO
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA225P6E  PVA Series: 225 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA225P6R  PVA Series: 225 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA300N6E  PVA Series: 300 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA300N6R  PVA Series: 300 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN Programmable for LO/DO
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA375P6EQ  NOPVA Series: 375 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 M12 Integral QD
- 
                            
    
    
    PVA375P6Q  PVA Series: 375 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 2 m M12 Pigtail QD
- 
                            
    
    
    PVA100N6  PVA Series: 100 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN (on receiver)
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA100N6E  PVA Series: 100 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA100N6R  PVA Series: 100 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN Programmable for LO/DO
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA100P6EQ W/6IN  PVA Series: 100 mm Array 
 Emitter; Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 150 mm (6 in) M12 Pigtail QD
- 
                            
    
    
    PVA100P6RQ W/6IN  PVA Series: 100 mm Array 
 Receiver; Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP
 150 mm (6 in) M12 Pigtail QD
- 
                            
    
    
    PVA225N6  PVA Series: 225 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN (on receiver)
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA225P6  PVA Series: 225 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA300N6EQ  PVA Series: 300 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 M12 Pigtail QD
- 
                            
    
    
    PVA300N6RQ  PVA Series: 300 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN Programmable for LO/DO
 M12 Pigtail QD
- 
                            
    
    
    PVA300P6  PVA Series: 300 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA300P6E  PVA Series: 300 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA300P6R  PVA Series: 300 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA375N6EQ  PVA Series: 375 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 M12 Pigtail QD
- 
                            
    
    
    PVA375N6Q  PVA Series: 375 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 NPN (on receiver)
 M12 Pigtail QD
- 
                            
    
    
    PVA375P6  PVA Series: 375 mm Array Pair - Emitter/Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP (on receiver)
 2 m (6.5 ft) Integral Cables
- 
                            
    
    
    PVA375P6E  PVA Series: 375 mm Array - Emitter 
 Range: 2 m; Input: 12-30 V dc
 Output: Not Applicable
 2 m (6.5 ft) Integral Cable
- 
                            
    
    
    PVA375P6R  PVA Series: 375 mm Array - Receiver 
 Range: 2 m; Input: 12-30 V dc
 Output: 1 PNP Programmable for LO/DO