EZ-SCREEN Low-Profile Safety Light Curtain Systems with Integral Muting

Overview

Low-Profile safety light curtain with continuous detection along the entire light screen length to eliminate "dead zones."

  • Low-profile, compact package for smaller production machines, yet robust enough for large power presses
  • Creates a screen of synchronized, modulated infrared sensing beams that extend from end to end of the housing (no "dead zone")
  • Built-in muting function, no third box required. Capable of two or four mute device/sensor hookup options
  • Seven different, predefined, muting configuration options, including Bypass, Mute-Dependent Override, Mute Enable, and Mute-cycle time extensions (4 seconds) for "L"-style cell exit applications
  • Selectable monitored/non-monitored Mute Lamp, Reset Status, and two OSSD Status Outputs to EZ-LIGHT (or other indicating devices) with RD cordset and accessory end-cap mounting bracket
  • Optional CSM Muting Splitter Cordset provides easy set up, less wiring, lower installation costs by providing a complete QD connectorized solution
  • Status, Reset, Zone, Mute Device and Diagnostic indicators and displays tell the number and location of beams blocked and provide detailed diagnostics minimizing downtime and troubleshooting
  • Set up can be performed without a PC, hand-held programmer, or other device; and DIP switch configuration features many of the same functions as a standard EZ-SCREEN Low Profile
  • 100 mm to 7 m (4" to 23') sensing range
  • Highly immune to EMI, RFI, ambient light, weld flash and strobe light

Product Specifications

Supply Voltage at the Device24V dc ±15% (use a SELV-rated power supply according to EN IEC 60950). (The external voltage supply must be capable of buffering brief mains interruptions of 20 ms, as specified in IEC/EN 60204-1)
Residual Ripple± 10% maximum
Supply CurrentEmitter:60 mA max. exclusive of Fault Out load



Receiver:150 mA max., exclusive of OSSD1 and OSSD2 loads (up to additional 0.5A each) and Aux Out load (up to 0.25 A)
AUX/Fault Output Switching CapacityCurrent-sourcing (PNP) solid-state output, 24V dc at 250 mA max.
Status IndicatorsOne bi-color (Red/Green) Status Indicator - indicates operating mode, lockout or power OFF condition



7-Segment Diagnostic indicator (1 digit) - indicates proper operation, scan code, or error code
Wavelength of Emitter ElementsInfrared LEDs, 850 nm at peak emission
Remote Test InputTest mode is activated either by applying a low signal (less than 3V dc) to emitter Test/Reset terminal for a minimum of 50 milliseconds, or by opening a switch connected between Test/Reset and +24V dc for a minimum of 50 milliseconds. Beam scanning stops to simulate a blocked condition. A high signal at Test/Reset deactivates Test mode.



High Signal: 10 to 30V dc



Low Signal: 0 to 3V dc



Input Current: 35 mA inrush, 10 mA max.
Controls and AdjustmentsScan Code Selection: 2-position switch (code 1 or 2). Factory default position is code 1.



Test/Reset: 2-position switch. Factory default position is Reset.



Invert Display: 2-position switch. Factory default position is OFF (standard display).



Fault: 2-position switch. Factory default position is OFF.
Response TimeDependent on number of sensing beams; see models table (manual p/n 150216) for number of beams and response time.
EDM Input+24V dc signals from external device contacts can be monitored (one-channel or no monitoring) via EDM1 terminal in the receiver.



High Signal: 10 to 30V dc at 30 mA typical



Low Signal: 0 to 3V dc
Output Signal Switching Devices (OSSDs)Two redundant solid-state 24V dc, 0.5 A max. sourcing OSSD (Output Signal Switching Device) safety outputs. (Use optional interface modules for ac or larger dc loads.) Capable of the Banner Safety Handshake.



ON-State voltage: > Vin-1.5V dc



OFF-State, maximum allowed voltage: 1.7V dc max.



Max. load capacitance: 1.0 μF



Min. load inductance: 10 H



Leakage Current: 0.50 mA max.



OSSD test pulse width: 100 to 300 microseconds typical



OSSD test pulse period: 10 ms to 22 ms (varies with number of beams)



Switching Current: 0-0.5 A
Auxiliary Output Switching Capacity (OSSD/Fault)Current-sourcing (PNP) solid-state output, 24V dc at 250 mA max.
Recovery TimeBlocked to Clear (OSSDs turn ON; varies with total number of sensing beams and whether Sync beam is blocked):



14 mm Models: 109 ms to 800 ms for Beam 1 (Sync Beam); 33ms to 220 ms for all other beams



25 mm Models: 81 ms to 495 ms for Beam 1; 25 ms to 152 ms for all other beams
Reset InputReset input must be high for 0.25 to 2 seconds and then low to reset the receiver



High Signal: 10 to 30V dc at 30 mA typical



Low Signal: 0 to 3V dc



Closed Switch Time: 0.25 to 2 seconds
Mute Lamp OutputA monitored or non-monitored (selectable), current-sourcing (PNP), solid-state output



Rated Current: 10 mA to 360 mA at 24V dc
External Remote Indicator OutputsCurrent sourcing (PNP), solid-state, 24 Vdc outputs for the connection of remote indicator lamps such as EZLIGHTs. See EZ-LIGHT™ for EZ-SCREEN® Low Profile with Muting on page 98 for compatible EZ-LIGHTs and associated cordsets.



Rated Current: 100 mA maximum at 24 Vdc
Controls and AdjustmentsScan Code selection: 2-position switch (code 1 or 2). Factory default position is code 1.



Trip/Latch Output selection: Redundant switches. Factory default position is T (trip).



Mute Lamp Monitoring: ON/OFF switch. Factory default position is ON.



Reduced Resolution: Redundant switches. Factory default position is OFF.



Aux./Fault: 2-position switch. Factory default position is Aux.



Invert Display: 2-position switch. Factory default position is OFF (standard display).
Status IndicatorsYellow Reset Indicator - indicates whether the system is ready for operation or requires a reset



Bi-color (Red/Green) Status indicator - indicates general system and output status



Bi-color (Red/Green) Zone Status indicators - indicate condition (clear or blocked beam) of a defined group of beams



7-Segment Diagnostic indicator (1 digit) - indicates proper operation, scan code, error code, or total number of blocked beams



Yellow Mute Device Input Indicators - indicates status of mute device inputs
Ambient Light Immunity10,000 lux at 5º angle of incidence
Strobe Light ImmunityTotally immune to one Federal Signal Corp.
Short Circuit ProtectionAll inputs and outputs are protected from short circuits to +24V dc or dc common.
Electrical Safety ClassIII (per IEC 61140: 1997)
Safety RatingType 4 per IEC 61496-1, -2



Category 4 PL e per EN ISO13849-1



SIL3 per IEC 61508; SIL CL3 per IEC 62061
Operating Range0.1 m to 7 m (4 in. to 23 ft.) — Range decreases with use of mirrors and/or lens shields:



* Lens shields — approx 10% less range per shield.



* Glass-surface mirrors — approx 8% less range per mirror



See the specific mirror datasheet for more information.
Resolution14 mm or 25 mm, depending on model (Reduced Resolution OFF)
Effective Aperture Angle (EAA)Meets Type 4 requirements per IEC 61496-2, Section 5.2.9



+ 2.5º @ 3 m
Operating ConditionsTemperature: 0° to +55° C (+32° to 131°F)



Max. Relative Humidity: 95% maximum relative humidity (non-condensing)
EnclosureExtruded aluminum housing with yellow polyester powder finish standard and well-sealed, rugged die-cast zinc end caps, acrylic lens cover, copolyester access cover.
RatingIEC IP65
Shock and VibrationComponents have passed vibration and shock tests according to IEC 61496-1. This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm (0.014 in.) single amplitude (0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles).
Mounting HardwareEmitter and receiver each are supplied with a pair of swivel end-mounting brackets and two swivel sidemount brackets. Models longer than 690 mm also include additional side-mount bracket(s) for center support. Mounting brackets are 8-gauge cold-rolled steel, black zinc finish.
Cables and ConnectionsSee Cordsets on page 90 (manual p/n 150216) for recommended cables. If other cables are used with the EZ-SCREEN LPM, the user must verify suitability of these cables for each application.
CertificationsCE, cTUVus

English

Product Instruction Manual

Document Name Part Number File Size Download
1. EZ-SCREEN LP with Integral Muting Instruction Manual 150216 Download
2. EZ-SCREEN LP Standard Bracket Supplement 147360 Download

Data Sheets

Document Name Part Number File Size Download
1. LPSS Series Snap-On Lens Shields 149566 Download

Checkout Procedures

Document Name Part Number File Size Download
1. EZ-SCREEN LP with Integral Muting Semi-Annual Checkout Card 150219 Download
2. EZ-SCREEN LP with Integral Muting Daily Checkout Card 150217 Download

French

Product Instruction Manual

Document Name Part Number File Size Download
1. EZ-SCREEN LP with Integral Muting Instruction Manual
(French)
160750 Download

Checkout Procedures

Document Name Part Number File Size Download
1. Semi-Annual Checkout Card - EZ-SCREEN LP with Muting
(French)
160752 Download
2. Daily Checkout Card - EZ-SCREEN LP with Muting
(French)
160751 Download

German

Product Instruction Manual

Document Name Part Number File Size Download
1. EZ-SCREEN LP with Integral Muting Instruction Manual
(German)
168720 Download

Checkout Procedures

Document Name Part Number File Size Download
1. Semi-Annual Checkout Card - EZ-SCREEN LP with Muting
(German)
168722 Download
2. Daily Checkout Card - EZ-SCREEN LP with Muting
(German)
168721 Download

Italian

Product Instruction Manual

Document Name Part Number File Size Download
1. EZ-SCREEN LP with Integral Muting Daily Card
(Italian)
168724 Download
2. EZ-SCREEN LP with Integral Muting Semi Card
(Italian)
168725 Download
3. EZ-SCREEN LP with Integral Muting Instruction Manual
(Italian)
168723 Download

Banner Insider eNewsletter

Helpful application information, new product updates, answers to frequently asked questions, and more.

Subscribe Now »

Banner Enhances Mobile Site

m.bannerengineering.com »
  • Search by part/model number
  • Easily locate distributors in your area
  • Share data from your phone or tablet

Worldwide Distributors

Banner has more than 3,000 distributors—ready to help you. Enter your U.S. city or zip.

07095 [change]

Find international distributors