| Supply Voltage (Limit Values) | Emitter:12 to 30V dc
Receiver analog current models:12 to 30V dc
Receiver analog voltage models:15 to 30V dc
|
| Supply Power Requirements | Emitter/receiver pair:less than 9 W (exclusive of load)
|
| Delay at Power-up | 2 seconds
|
| Emitter/Receiver Range | 400 mm to 4 m
|
| Field of View | Nominally ± 3°
|
| Beam Spacing | 5 mm
|
| Light Source | Infrared LED
|
| Minimum Object Detection Size | Straight scan, low-contrast:5 mm
Straight scan, high-excess-gain:10 mm
Note:See quick start guide p/n 126701 for other scan mode values; size is tested using a rod.
|
| Sensor Positional Resolution | Straight scan:5 mm
Double-edge scan:2.5 mm
Single-edge scan:2.5 mm
|
| Teach Input (Receiver Gray Wire) | Low:0 to 2 V
High:6 to 30 V or open (input impedance 22 K ohms)
|
| Output Configuration | Two discrete output and two analog output
Discrete outputs:Solid-State NPN (current sinking) or PNP (current sourcing)
Analog output:0 to 10V dc (voltage sourcing) or 4 to 20 mA (current sourcing)
|
| Output Rating | Discrete output:100 mA max. each output
OFF-state leakage current:
NPN:less than 200 uA @ 30V dc
PNP:less than 10 uA @ 30V dc
ON-state saturation voltage:
NPN:less than 1.6V @ 100 mA
PNP:less than 2.0V @ 100 mA
Analog voltage output:
Maximum current load:5 mA
Analog current output:
Maximum resistance load:(Vsupply–3) / 0.020
|
| Serial Communication Interface | EIA-485 Modbus RTU (up to 15 nodes per communication ring)
RTU binary format
Baud rate:9600, 19.2K or 38.4K, 8 Data Bits, 1 Stop Bit, and Even, Odd, or 2 Stop Bits and No Parity
|
| Scan Time | Scan times depend on scan mode and sensor length. Straight scan times range from 2.8 to 26.5 milliseconds.
|
| Status Indicators | Emitter:Red status indicators
Red ON steady:status OK
Red flashing @ 1 hz:error
Receiver:
7 Zone Indicators:
Red:blocked channels within zone
Green:all channels clear within zone
3-digit 7-segment indicators:measurement mode / diagnostic information
Sensor Status Bi-Color Indicator LED:
Red:hardware error or marginal alignment
Green:OK
Modbus Activity Indicator LED:Yellow
Modbus Error Indicator LED:Red
|
| System Configuration | 6-position DIP switch:Used to set scanning type, measurement modes, analog slope and discrete output 2 function. Alternate software GUI interface provides additional options; see Section 1 and Section 5 of the full manual (p/n 130426).
|
| Push Buttons (Receiver Interface) | Two momentary push buttons for alignment and gain level selection.
|
| Connections | Serial communication:The receiver uses a PVC-jacketed, 5-conductor 22-gauge quick-disconnect cable, 5.4 mm diameter. QD cables are ordered separately.
Other Sensor connections:8-conductor quick-disconnect cables (one each for emitter and receiver). Length may not exceed 75 meters long. PVC-jacketed cables measure 5.8 mm diameter, have shield wire; 22-gauge conductors. QD cables are ordered separately.
|
| Construction | Aluminum housing with clear-anodized finish; acrylic lens cover
|
| Environmental Rating | IEC IP65
|
| Operating Conditions | Temperature:–40° to +70° C
Relative humidity:95% at 50° C (non-condensing)
|