| Supply Voltage and Current | 85 to 264V ac, 50/60 Hz or 48 to 250V dc (1.5 W max. exclusive of load) |
|---|---|
| Range | 200 mm to 8 m |
| Ultrasonic Frequency | 75 kHz
Rep. rate:96 milliseconds |
| Supply Protection Circuitry | Protected against transient overvoltages |
| Output Configuration | SPDT (Single-Pole, Double Throw) electromechanical relay output. One normally open (NO) and one normally closed (NC) |
| Output Rating | Max. switching power (resistive load):2000 VA, 240 W (1000 VA, 120 W for sensors with Micro-style QD) Max. switching voltage (resistive load):250V ac, 125V dc Max. switching current (resistive load):8 A @ 250V ac, 8 A @ 30V dc derated to 200 mA @ 125V dc (4 A max. for sensors with Micro-style QD) Min. voltage and current:5V dc, 10 mA Mechanical life of relay:50,000,000 operations Electrical life of relay at full resistive load:100,000 operations Note:Transient suppression is recommended when switching inductive loads. |
| Output Protection | Protected against short circuit conditions |
| Output Response Time | Selectable 1600, 400 or 100 milliseconds |
| Delay at Power-up | 1.5 seconds |
| Temperature Effect | Uncompensated:0.2% of distance/° C Compensated:0.02% of distance/° C |
| Repeatability | 1.0 mm |
| Hysteresis | Window limit sensor models:5 mm Fill-level control sensor models:0 mm |
| Minimum Window Size | 20 mm |
| Adjustments | Sensing window limits:TEACH-Mode programming of near and far window limits may be set using the push buttons. Sensor Configuration:Output response time and temperature compensation mode may be set using the Speed push button. Factory default settings: 400 milliseconds output response time and temperature compensation enabled |
| Indicators | Green Power ON LED:indicates power is ON Red Signal LED:indicates target is within sensing range, and the condition of the received signal TEACH/Output indicator (bicolor Yellow/Red):indicates output status or TEACH mode Response indicator (bicolor Yellow/Red:indicates output response time selection |
| Construction | Transducer:ceramic/epoxy composite Housing:ABS Membrane switch:polyester |
| Environmental Rating | Leakproof design, rated IEC IP7; NEMA 6P |
| Connections | 5-conductor (with drain) 2 m or 9 m shielded PVC-jacketed attached cable, or 5-pin Micro- or Mini-style quick-disconnect fitting. QD cables are ordered separately. |
| Operating Conditions | Temperature:-20° to +70° C Relative humidity:100% |
| Vibration and Mechanical Shock | All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60 Hz max. double amplitude 0.06”, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 milliseconds duration, half-sine wave. |
| Temperature Warmup Drift | Less than 1.0% of sensing distance upon power-up with Temperature Compensation enabled |
| Application Note | Objects passing inside the specified near limit (200 mm) may produce a false response. |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | U-GAGE QT50U Series, Electromechanical Relay Output (ac/dc models) |
117764 | 2.6MB | Download Email |
| 2. | U-GAGE QT50U Series, Mounting Flange (SAFQT50U) |
116804 | 455K | Download Email |
| 3. | U-GAGE QT50U, T30U Series, Teflon Flange | 122155 | 420K | Download Email |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »Browse by model family or type in your model number to find STEP, IGS, DXF, or PDF files for your project.
Find them now »Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code