| Supply Voltage at the Device | 24V dc ±15% (use a SELV-rated power supply according to EN IEC 60950). (The external voltage supply must be capable of buffering brief mains interruptions of 20 ms, as specified in IEC/EN 60204-1) |
|---|---|
| Residual Ripple | ± 10% maximum |
| Supply Current | Emitter:60 mA max. exclusive of Fault Out load Receiver:150 mA max., exclusive of OSSD1 and OSSD2 loads (up to additional 0.5A each) and Aux Out load (up to 0.25 A) |
| AUX/Fault Output Switching Capacity | Current-sourcing (PNP) solid-state output, 24V dc at 250 mA max. |
| Status Indicators | One bi-color (Red/Green) Status Indicator - indicates operating mode, lockout or power OFF condition 7-Segment Diagnostic indicator (1 digit) - indicates proper operation, scan code, or error code |
| Wavelength of Emitter Elements | Infrared LEDs, 850 nm at peak emission |
| Remote Test Input | Test mode is activated either by applying a low signal (less than 3V dc) to emitter Test/Reset terminal for a minimum of 50 milliseconds, or by opening a switch connected between Test/Reset and +24V dc for a minimum of 50 milliseconds. Beam scanning stops to simulate a blocked condition. A high signal at Test/Reset deactivates Test mode. High Signal: 10 to 30V dc Low Signal: 0 to 3V dc Input Current: 35 mA inrush, 10 mA max. |
| Controls and Adjustments | Scan Code Selection: 2-position switch (code 1 or 2). Factory default position is code 1. Test/Reset: 2-position switch. Factory default position is Reset. Invert Display: 2-position switch. Factory default position is OFF (standard display). Fault: 2-position switch. Factory default position is OFF. |
| Response Time | Dependent on number of sensing beams; see models table (manual p/n 150216) for number of beams and response time. |
| EDM Input | +24V dc signals from external device contacts can be monitored (one-channel or no monitoring) via EDM1 terminal in the receiver. High Signal: 10 to 30V dc at 30 mA typical Low Signal: 0 to 3V dc |
| Output Signal Switching Devices (OSSDs) | Two redundant solid-state 24V dc, 0.5 A max. sourcing OSSD (Output Signal Switching Device) safety outputs. (Use optional interface modules for ac or larger dc loads.) Capable of the Banner Safety Handshake. ON-State voltage: > Vin-1.5V dc OFF-State, maximum allowed voltage: 1.7V dc max. Max. load capacitance: 1.0 μF Min. load inductance: 10 H Leakage Current: 0.50 mA max. OSSD test pulse width: 100 to 300 microseconds typical OSSD test pulse period: 10 ms to 22 ms (varies with number of beams) Switching Current: 0-0.5 A |
| Auxiliary Output Switching Capacity (OSSD/Fault) | Current-sourcing (PNP) solid-state output, 24V dc at 250 mA max. |
| Recovery Time | Blocked to Clear (OSSDs turn ON; varies with total number of sensing beams and whether Sync beam is blocked): 14 mm Models: 109 ms to 800 ms for Beam 1 (Sync Beam); 33ms to 220 ms for all other beams 25 mm Models: 81 ms to 495 ms for Beam 1; 25 ms to 152 ms for all other beams |
| Reset Input | Reset input must be high for 0.25 to 2 seconds and then low to reset the receiver High Signal: 10 to 30V dc at 30 mA typical Low Signal: 0 to 3V dc Closed Switch Time: 0.25 to 2 seconds |
| Mute Lamp Output | A monitored or non-monitored (selectable), current-sourcing (PNP), solid-state output Rated Current: 10 mA to 360 mA at 24V dc |
| External Remote Indicator Outputs | Current sourcing (PNP), solid-state, 24 Vdc outputs for the connection of remote indicator lamps such as EZLIGHTs. See EZ-LIGHT™ for EZ-SCREEN® Low Profile with Muting on page 98 for compatible EZ-LIGHTs and associated cordsets. Rated Current: 100 mA maximum at 24 Vdc |
| Controls and Adjustments | Scan Code selection: 2-position switch (code 1 or 2). Factory default position is code 1. Trip/Latch Output selection: Redundant switches. Factory default position is T (trip). Mute Lamp Monitoring: ON/OFF switch. Factory default position is ON. Reduced Resolution: Redundant switches. Factory default position is OFF. Aux./Fault: 2-position switch. Factory default position is Aux. Invert Display: 2-position switch. Factory default position is OFF (standard display). |
| Status Indicators | Yellow Reset Indicator - indicates whether the system is ready for operation or requires a reset Bi-color (Red/Green) Status indicator - indicates general system and output status Bi-color (Red/Green) Zone Status indicators - indicate condition (clear or blocked beam) of a defined group of beams 7-Segment Diagnostic indicator (1 digit) - indicates proper operation, scan code, error code, or total number of blocked beams Yellow Mute Device Input Indicators - indicates status of mute device inputs |
| Ambient Light Immunity | 10,000 lux at 5º angle of incidence |
| Strobe Light Immunity | Totally immune to one Federal Signal Corp. |
| Short Circuit Protection | All inputs and outputs are protected from short circuits to +24V dc or dc common. |
| Electrical Safety Class | III (per IEC 61140: 1997) |
| Safety Rating | Type 4 per IEC 61496-1, -2 Category 4 PL e per EN ISO13849-1 SIL3 per IEC 61508; SIL CL3 per IEC 62061 |
| Operating Range | 0.1 m to 7 m (4 in. to 23 ft.) — Range decreases with use of mirrors and/or lens shields: * Lens shields — approx 10% less range per shield. * Glass-surface mirrors — approx 8% less range per mirror See the specific mirror datasheet for more information. |
| Resolution | 14 mm or 25 mm, depending on model (Reduced Resolution OFF) |
| Effective Aperture Angle (EAA) | Meets Type 4 requirements per IEC 61496-2, Section 5.2.9 + 2.5º @ 3 m |
| Operating Conditions | Temperature: 0° to +55° C (+32° to 131°F) Max. Relative Humidity: 95% maximum relative humidity (non-condensing) |
| Enclosure | Extruded aluminum housing with yellow polyester powder finish standard and well-sealed, rugged die-cast zinc end caps, acrylic lens cover, copolyester access cover. |
| Rating | IEC IP65 |
| Shock and Vibration | Components have passed vibration and shock tests according to IEC 61496-1. This includes vibration (10 cycles) of 10-55 Hz at 0.35 mm (0.014 in.) single amplitude (0.70 mm peak-to-peak) and shock of 10 g for 16 milliseconds (6,000 cycles). |
| Mounting Hardware | Emitter and receiver each are supplied with a pair of swivel end-mounting brackets and two swivel sidemount brackets. Models longer than 690 mm also include additional side-mount bracket(s) for center support. Mounting brackets are 8-gauge cold-rolled steel, black zinc finish. |
| Cables and Connections | See Cordsets on page 88 (manual p/n 150216) for recommended cables. If other cables are used with the EZ-SCREEN LPM, the user must verify suitability of these cables for each application. |
| Certifications | CE, cTUVus |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | EZ-SCREEN LP Standard Bracket Supplement | 147360 | 441K | Download Email |
| 2. | EZ-SCREEN LP with Integral Muting Instruction Manual | 150216 | 8.9MB | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | LPSS Series Snap-On Lens Shields | 149566 | 74K | Download Email |
| Document Name | Part Number | File Size | Download | |
|---|---|---|---|---|
| 1. | EZ-SCREEN LP with Integral Muting Daily Checkout Card | 150217 | 416K | Download Email |
| 2. | EZ-SCREEN LP with Integral Muting Semi-Annual Checkout Card | 150219 | 214K | Download Email |
Helpful application information, new product updates, answers to frequently asked questions, and more.
Subscribe Now »The source for all Banner product lines. Features multiple navigation options, applications and product comparisons, and detailed specifications for brackets, cordsets and other accessories.
Get it Now »Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code