| Supply Voltage and Current | 10 to 30V dc (10% max. ripple within specified voltage range); 36 mA exlusive of load
|
| Supply Protection Circuitry | Protected against reverse polarity and transient voltages
|
| Output Configuration | Bipolar; one current sourcing (PNP) and one current sinking (NPN)
|
| Output Rating | 150 mA max. (each output)
Off-state leakage current:<10 microamps
NPN saturation:< 200 mV at 10 mA and < 1.0V at 150 mA
PNP saturation:< 1V at 10 mA and < 2.0V at 150 mA
|
| Output Protection Circuitry | Protected against false pulse on power-up and continuous overload or short-circuit of outputs
|
| Output Response Time | 50 microseconds: 100 millisecond delay on power-up (outputs do not conduct)
|
| Repeatability | 15 microseconds
|
| Sensing Image | Rectangular: 1.2 mm x 3.8 mm (0.05
|
| Adjustments | Light/Dark Operate (LO/DO) select switch, and 15-turn switchpoint adjustment potentiometer
|
| Indicators | 1 Amber:Output active
2 Green:Switchpoint threshhold adjustment indicators
|
| Construction | Housing:Zinc alloy die-cast housing with black painted finish and o-ring sealed lens port cap
Lens:Acrylic
Lens port cap and lens holder:ABS
Sensitivity and LO/DO adjusters:Acetal
QD:Anodized aluminum
|
| Environmental Rating | IEC IP67; NEMA 6
|
| Connections | PVC-jacketed 4-conductor 2 m (6.5'); 9 m (30') attached cable; integral 4-pin Euro-style QD fitting; or 150 mm (6
|
| Operating Conditions | Temperature:10° to 55° C (+14° to 131° F)
Storage Temperature:-20° to 80° C (-4° to 185° F)
Maximum relative humidity:90% at 50°C (non-condensing)
|
| Vibration and Shock | All models meet IEC 68-2-6 and IEC 68-2-27 testing criteria
|
| Application Notes | 1:Do not mount the sensor directly perpendicular to shiny surfaces; position it at approximately 15 angle in relation to the sensing target.
2:Minimize web or product
3:The lens may be installed in either of the two lens ports. The lens port cap must be installed on the unused port for reliable operation.
|