FlexPower Nodes with Temperature I/O

These Nodes are available with temperature I/O, either for thermocouples, RTDs, or temperature/humidity serial sensors. Unless the model specifies that it contains a battery integrated into the housing, these models may be powered by 10-30V dc, DX81 Battery Supply Modules, or the Solar Power Assembly.

Models ending in C use external terminal blocks instead of internal terminal blocks. These C models are Class I, Division 2 certified when installed in a suitable enclosure. Certifications are listed on the Classified Areas page. Refer to the 3D Models page to download AutoCAD, STEP, IGES, and PDF models.

SureCross Performance Nodes

These SureCross Performance Nodes are designed to function with the SureCross Performance Gateways, but may be also be configured to work with the existing DX80 Gateways. Refer to the 3D Models page to download AutoCAD, STEP, IGES, and PDF models.

  • Enhanced Nodes offer increased range in the 900 MHz frequency band
  • High density I/O capacity provides up to 12 discrete inputs or outputs or up to four temperature inputs (thermocouple or RTD)
  • New “environmental” housing option provides integrated battery and wiring terminals all in one unit
  • Universal analog inputs allow current or voltage to be selected in the field

DX80 Performance Node DX80 Performance Node (E Housing)
SureCross Performance Node SureCross Performance Node, "E" Housing Style

Model Frequency Power I/O Data Sheet
DX80N9X2S-P1 900 MHz 10 to 30V dc, solar, or battery power sources Discrete Mode
Inputs: Two selectable discrete and two thermistor
Outputs: Two NMOS/sinking discrete
Switch Power: Two

Analog Mode
Inputs: Two selectable discrete, two analog (0–20 mA or 0–10V), and two thermistor
Outputs: Two NMOS/sinking discrete
Switch Power: One

155748
DX80N2X2S-P1 2.4 GHz
DX80N9X1S-P1E 900 MHz 10 to 30V dc or integrated battery
DX80N2X1S-P1E 2.4 GHz
DX80N9X2S-P3 900 MHz 10 to 30V dc, solar, or battery power sources Inputs: Two selectable discrete, four thermocouple, one thermistor for CJC
Outputs: One NMOS sinking discrete
155863
DX80N2X2S-P3 2.4 GHz
DX80N9X1S-P3E 900 MHz 10 to 30V dc or integrated battery
DX80N2X1S-P3E 2.4 GHz
DX80N9X2S-P4 900 MHz 10 to 30V dc, solar, or battery power sources Inputs: Four 3-wire RTDs 155864
DX80N9X1S-P4E 10 to 30V dc or integrated battery

DX80 Nodes

The standard IP67 base with internal terminal blocks The low-profile IP20 base with external terminal blocks.

Model Frequency Base I/O Data Sheet
DX80N9X2S2N2T 900 MHz IP67 Thermocouple: Three inputs, one thermistor CJC input
Discrete: Two selectable inputs, two NMOS sinking outputs
131297
DX80N9X2S2N2TC IP20
DX80N2X2S2N2T 2.4 GHz IP67
DX80N2X2S2N2TC IP20
DX80N9X2S0P0R 900 MHz IP67 RTD: Four three-wire inputs 131597
DX80N9X2S0P0RC IP20
DX80N2X2S0P0R 2.4 GHz IP67
DX80N2X2S0P0RC IP20

To order the internal antenna models, replace the "S" in the 9th digit with a "W." Internal antennas require an additional week for manufacture and shipping. For example, DX80N9X2S2N2T is the model number for the external antenna device and DX80N9X2W2N2T is the internal antenna device.

Models with batteries integrated into the housing are so noted. For all other FlexPower models, the DX81 or DX81P6 Battery Supply Modules must be ordered separately to power these devices from battery.

Wireless FlexPower Nodes with Serial I/O

Standard FlexPower base Battery integrated into the housing

Model Frequency Base I/O Data Sheet
DX80N9X2S2S 900 MHz Standard One serial port to handle up to two serial temperature and humidity sensors. 136971
DX80N2X2S2S 2.4 GHz
DX80N9X1S1S 900 MHz Integrated Battery One serial port to handle one serial temperature and humidity sensor. 137322
DX80N2X1S1S 2.4 GHz

To order the internal antenna models, replace the "S" in the 9th digit with a "W." Internal antennas require an additional week for manufacture and shipping. For example, DX80N9X2S1S is the model number for the external antenna device and DX80N9X2W1S is the internal antenna device.

Models with batteries integrated into the housing are so noted. For all other FlexPower models, the DX81 or DX81P6 Battery Supply Modules must be ordered separately to power these devices from battery.

Banner Insider eNewsletter

Helpful application information, new product updates, answers to frequently asked questions, and more.

Subscribe Now »

Built-to-Order Tower Lights

  • Preassembled, custom-configured
  • Optional audible function
  • 5 colors, standard or high-brightness LEDs.
Configure your Tower Light »

Worldwide Distributors

Banner has more than 3,000 distributors worldwide — ready to help you. Enter a U.S. zip code


Find international distributors