SC22-3 Safety Controller

Overview

Totally configurable safety controller monitors numerous safety devices such as E-stop buttons, interlocking switches, safety light screens, two-hand controls and rope pull switches.

  • 22 input terminals can monitor both contact-based or PNP solid-state outputs from Banner devices or any other manufacturers
  • Each input can be a non-safety input, or configured for Control Reliability or Category 2, 3 or 4 safety circuit performance per ISO 13849-1
  • 3 pairs of solid-state safety outputs rated at 0.75A each (24V dc) with selectable one- or two-channel external device monitoring and ON-delay or OFF-delay
  • 10 configurable auxiliary status outputs track inputs, outputs, lockout, I/O status and other functions
  • Easy configuration with built-in front panel LCD display or PC Interface
  • Live Display and a Fault Log provide real-time system and fault history identification
  • Controller is designed to meet stringent standards including Safety Integrity Level (SIL) 3 per IEC 62061 and IEC 61508, and Category 4 Performance Level (PL e) per ISO 13849-1

Product Specifications

Safety and Non-Safety Inputs (22 terminals)Input ON threshold:greater than 15V dc (guaranteed on), 30V dc max.
Input OFF threshold:less than 5V dc (guaranteed off with any 1 fault), –3V dc min.
Input ON current:8 mA typical @ 24V dc, greater 2 mA (guaranteed with 1 fault); 50 mA peak contact cleaning current @ 24V dc
Sourcing current:30 mA minimum continuous (3V dc max. drop)
Input lead resistance:300 ohms max. (150 ohms per lead)
Power24V dc, ± 20%

0.4 A (controller only), 5.9 A (all outputs ON @ full rated load)



The Controller should be connected only to a SELV or PELV power supply.
Safety Outputs (6 terminals, 3 redundant outputs)Rated output current:0.75 A max. @ 24V dc (1.0V dc max. drop)
Output OFF threshold:0.9V dc typical (1.2V dc max. guaranteed with 1 fault)
Output leakage current:50 μA max. with open 0V
Load:0.1 μF max., 1 H max., 10 ohms max. per lead
Status Outputs (10 terminals)Rated output current:0.5A @ 24V dc (individual), 1.0 A @ 24V dc (total of all outputs)
O1 to O8 (General Purpose) Output OFF voltage:less than 0.5V dc (no load)
O9 and O10 (Monitored Mute Lamp) Output OFF voltage:internal 94 kohms pull up to V supply
O9 and O10 (Monitored Mute Lamp) Output ON/OFF threshold:15V dc +/-4V dc @ 24V dc supply
Note:For O9 and O10, if a short circuit or other fault condition causes the output to drop below this threshold while the output is ON, a lockout will occur. If an open circuit or other fault condition causes the output to rise above this threshold while the output is OFF, a lockout will occur.
Response and Reaction TimesResponse time (ON to OFF):10 milliseconds max. (with standard 6 milliseconds debounce; this can increase if debounce time increases. Refer to the configuration summary for actual response time.)
Reaction time (OFF to ON):400 milliseconds max. (with manual reset option)
Reaction time (OFF to ON):400 milliseconds max. plus input debounce time (auto reset)
Onboard LCD Information Display—Password RequirementsPassword is not required:

Run mode (I/O status)

Fault (I/O fault detection and remedial steps)

Review configuration parameters (I/O properties and terminals)

Password is required:

Configuration mode (create/modify/confirm/download configurations)
Environmental RatingNEMA 1 (IEC IP20), for use inside NEMA 3 (IEC IP54) or better enclosure
Operating ConditionsTemperature range:0° to +55° C
Mechanical StressShock:15 g for 11 milliseconds, half sine, 18 shocks total (per IEC 61131-2)
Bump:10 g for 16 milliseconds, 6000 cycles total (per IEC 61496-1)
Vibration:3.5 mm occasional / 1.75 mm continuous @ 5Hz to 9 Hz, 1.0 g occasional and 0.5 g continuous @ 9 to 150 Hz: (per IEC 61131-2) and 0.35 mm single amplitude / 0.70 mm peak-to-peak @ 10 to 55 Hz (per IEC 61496-1), all @ 10 sweep cycles per axis
EMCMeets or exceeds all EMC requirements in IEC 61131-2, IEC 61496-1 (Type 4), and IEC 62061 Annex E, Table E.1 (increased immunity levels)
Removable TerminalsScrew terminals:
Wire sizes:16, 18, 20, 22 or 24 AWG (0.20 – 1.31 mm2)
Wire strip length:5.00 mm
Tightening torque:0.23 Nm (2 in. lbs) nominal
Tightening torque:0.34 Nm (3.0 in. lbs) maximum
Clamp terminals:
Wire size:16, 18, 20, 22, or 24 AWG (0.20 – 1.31 mm2)
Wire strip length:9.00 mm
Important:The clamp terminals are designed for 1 wire only. If more than 1 wire is connected to a terminal, a wire could loosen or become completely disconnected from the terminal, causing a short.
Product Performance Standards*SIL 3 per IEC 62061 Safety of Machinery – Functional Safety of Safety-Related Electrical, Electronic and Programmable Electronic Control Systems.



*SIL 3 per IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems



*Category 4 per ISO 13849-1 (EN954-1) Safety of Machinery. Safety Related Parts of Control Systems



*Performance Level (PL) e per ISO 13849-1



*IEC 61131-2 Programmable Controllers, Part 2: Equipment Requirements and Tests



*UL 508 Industrial Control Equipment



*UL 1998 Software in Programmable Components



*ANSI NFPA 79 Electrical Standards for Industrial Machinery



*IEC 60204-1 Electrical Equipment of Machines: General Requirements



*EN 954-1 Safety of Machinery. Safety Related Parts of Control Systems. General Principles.



*ISO 13851 (EN574) Safety of Machinery – Two-Hand Control Devices – Functional Aspects and Design Principles



*ISO 13850 (EN418) Emergency Stop Devices

English

Product Instruction Manual

Document Name Part Number File Size Download
1. SC22-3, SC22-3E Safety Controller 133487 Download
2. SC22-3, SC22-3E Safety Controller Configuration Tutorial 154613 Download

Installation Guides

Document Name Part Number File Size Download
1. SC22-3 Safety Controller Quick Start Guide 133485 Download

Success Stories

Document Name Part Number File Size Download
1. Simplifying Safety Feature Management B_3126932 Download

Product Brochures

Document Name Part Number File Size Download
1. SC22-3/-3E Safety Controller Brochure 134777 Download

French

Product Instruction Manual

Document Name Part Number File Size Download
1. SC22-3 Safety Controller Instruction Manual - French 135453 Download

German

Product Instruction Manual

Document Name Part Number File Size Download
1. SC22-3 Safety Controller Instruction Manual - German 135454 Download

Japanese

Product Instruction Manual

Document Name Part Number File Size Download
1. SC22-3 and SC22-3E Safety Controller - Japanese JP133487 Download

United Kingdom

Product Instruction Manual

Document Name Part Number File Size Download
1. SC22-3 Safety Controller Instruction Manual - UK English 135369 Download

Demo

Banner Insider eNewsletter

Helpful application information, new product updates, answers to frequently asked questions, and more.

Subscribe Now »

"No more costly wiring runs"

“I’m delighted with Banner’s SureCross wireless system. It gives us comprehensive monitoring and control in previously inaccessible locations. And it’s easy to expand and relocate as needed.”

Worldwide Distributors

Banner has more than 3,000 distributors—ready to help you. Enter your U.S. city or zip.

07095 [change]

Find international distributors