cart

T30UDNB

Item Detail T30U Series 2 m Range Pump Control Ultrasonic Sensor
T30UDNB

Certifications

  • 041887_0_000; 3211-03 and 041887_0_000; 3211-83.
  • CE
Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Time of Flight
Housing Style
Barrel
Primary Housing Material
PBT
Indicator
LED(s)
Analog Resolution/Discrete Repeatability
+/- 0.25% of measured distance (1.0 mm min)
Max Sensing Distance (mm)
2000
Minimum Sensing Distance (mm)
300
Sensing Beam
Ultrasonic
Power Supply
12-24 V dc
Adjustments
Teach Button
Temperature Effect (mm/°C)
0.2% of sensing distance/°C
Connection
Cable
QD Type/Cable Length
2 m
Number of Pins
5
Vibration
MIL-STD-202F req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage NPN Outputs
< 1.0 V at 10 mA ; < 1.5 V at 100 mA
Max Discrete (Switched) Output (mA)
100
Discrete (Switched) Outputs
2 NPN
Output Protection
Protected against false pulse on power-up and continuous overload or short-circuit of outputs
IP Rating
IP67
NEMA Rating
NEMA 6P
Max Operating Temperature (°C)
70
Min Operating Temperature (°C)
-20
Max Op. Relative Humidity Non-Condensing (%)
100
Warm-up Time (minutes)
15
Temperature Warm-up Drift upon Power-up
< 1.7% of the sensing distance upon power-up.
Temp. Warm-up Drift (Notes 1)
After 10 min, the apparent distance is < 0.3% of the actual position.
Temp. Warm-up Drift (Notes 2)
After 25 min, the sensing position will be stable.
Minimum Response Time (ms)
96
Barrel Diameter (mm)
30
Minimum Window Size (mm)
10
Remote Teach and Laser Control Input Impedence
55 kΩ
Discrete Output Hysteresis (mm)
2.5
Ultrasonic Frequency (kHz)
128
Max Off-state Leakage Current (µA)
10
Power/Current Consumption (exclusive of load)
90 mA
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Clear Object Detection
Yes
Feature: Timing (Hold/Delay)
No
Feature: Chemical Resistant
No
Feature: Pump-in/ Pump-out
No
Application: Ultrasonic
Yes
IO Link
No
Wireless
No
Input/Output
Discrete

CAD Files

Date
Type
Size
T30U NB/PB CABLE/PIGTAIL
T30U NB/PB CABLE/PIGTAIL
25 May 2011
DXF
600K
T30U NB/PB CABLE/PIGTAIL
T30U NB/PB CABLE/PIGTAIL
25 May 2011
IGS
2.3MB
T30U NB/PB CABLE/PIGTAIL
T30U NB/PB CABLE/PIGTAIL
25 May 2011
PDF
85K
T30U NB/PB CABLE/PIGTAIL
T30U NB/PB CABLE/PIGTAIL
25 May 2011
STP
1.6MB

Technical Literature

Date
Type
Size
U-GAGE T30U Ultrasonic Series, Discrete Outputs
U-GAGE T30U Ultrasonic Series, Discrete Outputs
18 Feb 2013
DATA SHEET
499K

Certification

Date
Type
Size
DoC for T30U and T30UX
DoC for T30U and T30UX
12 Jun 2017
CERTIFICATION
456K
T30UDNB
T30UDNB
Item Detail: T30U Series 2 m Range Pump Control Ultrasonic Sensor

Certifications

  • 041887_0_000; 3211-03 and 041887_0_000; 3211-83.
  • CE