Q4XFULAF610-Q8
Item Detail Q4X Series Rugged Laser Distance Sensor
Certifications
Compatible Amplifiers
Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.
Accessories to Complete Your System
Add all or individual items to your cart. More options available below.
Specifications
- Sensing Beam
- Visible Red Laser
- PC Configurable
- No
- Sensing Mode (General)
- Proximity
- Sensing Mode (Detailed)
- Background/Foreground Suppression
- Housing Style
- Rectangular
- Primary Housing Material
- Stainless Steel
- Laser Classification
- Class 1
- Input/Output
- Analog
- Indicator
- Display; LED(s)
- Connection
- Integral QD
- Analog Output Configuration
- 0-10 V dc
- Analog Resolution/Discrete Repeatability
- 25 mm to 100 mm: +/- 0.5 mm, 100 mm to 600 mm: +/- 0.5%
- Quick Disconnect Type
- M12 (Euro)
- Max Sensing Distance (mm)
- 610
- Minimum Sensing Distance (mm)
- 35
- Sensing Beam
- Visible Red Laser
- Power Supply
- 12-30 V dc
- Delay at Power-up (ms)
- 750
- Sensing Beam Wavelength (nm)
- 655
- Adjustments
- Push Button; Remote Teach
- Temperature Effect (mm/°C)
- 1 mm/°C
- Number of Pins
- 5
- Vibration
- MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
- Mechanical Shock
- MIL-STD-202G, Meth. 213B, Cond. I (100G 6x along X, Y & Z axes, 18 total shocks) w/ sensor operating
- Analog Voltage Output Rating
- 2.5 kΩ min. load impedance
- Output Protection
- Protected against continuous overload and short circuit
- IP Rating
- IP67; IP68; IP69
- Storage Temperature (°C)
- -25 to 75
- Max Operating Temperature (°C)
- 50
- Min Operating Temperature (°C)
- -10
- Max Op. Relative Humidity Non-Condensing (%)
- 95 at 55°C
- Window Material
- Acrylic
- Warm-up Time (minutes)
- 10
- Minimum Response Time (ms)
- 0.5
- Spot Size (@ Reference Distance)
- 1.9 mm x 1.0 mm @ 610 mm
- Analog Linearity (mm)
- +/- 0.75 mm from 25 to 50 mm, 9.0 mm at 300 mm, 28 mm at 600 mm
- Minimum Window Size (mm)
- 2
- Laser Control
- Yes
- Max Ambient Light (Lux)
- 5000
- Power/Current Consumption (exclusive of load)
- < 700mW
- Supply Protection Circuitry
- Protected against reverse polarity and transient overvoltages
- Feature: Remote Teach
- Yes
- Feature: Washdown Rated
- Yes
- Feature: Timing (Hold/Delay)
- No
- Feature: Chemical Resistant
- Yes
- IO Link
- No
- RS-232
- No
- RS-422
- No
- RS-485
- No
- SSI
- No
- Wireless
- No
- 1-wire Serial Interface
- No
- Profibus
- No
Q4XFULAF610-Q8
Item Detail: Q4X Series Rugged Laser Distance Sensor