LE250IC1Q

Item Detail LE Series 1 m Range Laser Displacement Sensor
LE250IC1Q
LE250IC1Q
LE250IC1Q

Certifications

  • NRKH NRKH7 Vol1 Sec7
  • CE
Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Triangulation
Housing Style
Rectangular
Primary Housing Material
Zinc Alloy Die-Cast
Laser Classification
Class 1
Indicator
LCD; LED(s)
Analog Output Configuration
4-20 mA
Analog Resolution/Discrete Repeatability
100 mm to 250 mm: < 0.02 mm; 250 mm to 400 mm: < 0.2 mm
Max Sensing Distance (mm)
400
Minimum Sensing Distance (mm)
100
Sensing Beam
Visible Red Laser
Power Supply
12-30 V dc
Delay at Power-up (ms)
2000
Sensing Beam Wavelength (nm)
650
Adjustments
Push Button; Remote Teach
Temperature Effect (mm/°C)
+/- 0.03 mm/°C from 100 to 250 mm, +/- 0.15 mm /°C at 1000 mm
Connection
Integral QD
QD Type/Cable Length
M12 (Euro) requires mating cordset
Number of Pins
5
Vibration
MIL-STD-202G req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage NPN Outputs
< 1.6 V at 100 mA
Output Saturation Voltage PNP Outputs
< 3 V at 100 mA
Analog Current Output Rating
1 kΩ max @24 V dc, max load resistance = [(Vcc-4.5 V)/0.02 A] Ω
Max Discrete (Switched) Output (mA)
100
Discrete (Switched) Outputs
1 NPN/PNP Configurable
Output Protection
Protected against continuous overload and short circuit
IP Rating
IP67
NEMA Rating
NEMA 6
Storage Temperature (°C)
-30 to 65
Max Operating Temperature (°C)
55
Min Operating Temperature (°C)
-20
Max Op. Relative Humidity Non-Condensing (%)
90 at 55°C
Window Material
Acrylic
Warm-up Time (minutes)
10
Minimum Response Time (ms)
2
Spot Size (@ Reference Distance)
0.9 mm x 1.2 mm @ 400 mm
Analog Linearity (mm)
Linearity is the lesser of Accuracy or 0.3% of full scale range (± 0.9 mm) at any given distance
Minimum Window Size (mm)
1
Remote Teach and Laser Control Input Impedence
18 kΩ min. (65 kΩ min at 5 V dc)
Discrete Output Hysteresis (mm)
Automatically adjusted
Laser Control
Yes
Alarm Output (mA)
100
Max Ambient Light (Lux)
5000
Max Off-state Leakage Current (µA)
NPN: < 200 at 30 V dc; PNP: < 10 at 30 V dc
Power/Current Consumption (exclusive of load)
70 mA @ 24 V dc
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Timing (Hold/Delay)
Yes
Feature: Chemical Resistant
No
Feature: Health/ Marginal Signal Output
Yes
IO Link
No
Wireless
No
Input/Output
Analog & Discrete

CAD Files

Date
Type
Size
L-GAGE LE SERIES QD
6 Aug 2014
PDF
235K
L-GAGE LE SERIES QD
6 Aug 2014
DXF
994K
L-GAGE LE SERIES QD
6 Aug 2014
STP
3.7MB
L-GAGE LE SERIES QD
6 Aug 2014
IGS
2.4MB

Technical Literature

Date
Type
Size
L-GAGE LE250/550 Analog/Discrete Laser Gauging Sensors - Instruction Manual
6 Nov 2015
PRODUCT MANUAL
3.9MB
L-GAGE LE250/550 Analog/Discrete Laser Gauging Sensors - Quick Start Guide
6 Nov 2015
INSTALLATION GUIDE
832K

Certification

Date
Type
Size
DoC  for LE Series
2 Jun 2017
CERTIFICATION
455K

Single Ended Cordsets

Description
MQDEC2-506
MQDEC2-515
MQDEC2-530

Accessories

Description
SMBLEU
SMBLEL
SMBLEFA
SMBAMSLEIP
SMBAMSLTFP
RWAMSLE
LE250IC1Q
LE250IC1Q
Item Detail: LE Series 1 m Range Laser Displacement Sensor

Certifications

  • NRKH NRKH7 Vol1 Sec7
  • CE