T30UINB

Item Detail T30U Series 2 m Range Pump Control Ultrasonic Sensor
T30UINB

Certifications

  • CE

Compatible Amplifiers

Where applicable, maximum range for opposed mode fibers is also dependent on fiber length.

Accessories to Complete Your System

Add all or individual items to your cart. More options available below.

Cable Length (m)
2
Sensing Mode (General)
Proximity
Sensing Mode (Detailed)
Time of Flight
Housing Style
Barrel
Device Type
Sensor
Primary Housing Material
PBT
Input/Output
Analog & Discrete
Indicator
LED(s)
Analog Output Configuration
4-20 mA
Connection
Cable
Quick Disconnect Type
No QD
Analog Resolution/Discrete Repeatability
+/- 0.25% of measured distance (1.0 min)
Max Sensing Distance (mm)
2000
Minimum Sensing Distance (mm)
300
Sensing Beam
Ultrasonic
Power Supply
12-24 V dc
Adjustments
Teach Button
Temperature Effect (mm/°C)
0.2% of sensing distance/°C
Number of Pins
5
Vibration
MIL-STD-202F req. Method 201A (vibration:10 to 60Hz max., double amplitude 0.06", max acc. 10G).
Mechanical Shock
IEC 60947-5-2 requirements: 30G 11 ms duration, half sine wave
Output Saturation Voltage NPN Outputs
< 1.0 V at 10 mA ; < 1.5 V at 100 mA
Analog Current Output Rating
1 Ω to [(Vcc-7 V)/0.02 A] Ω
Max Discrete (Switched) Output (mA)
100
Discrete (Switched) Outputs
1 NPN
Output Protection
Protected against false pulse on power-up and continuous overload or short-circuit of outputs
IP Rating
IP67
NEMA Rating
NEMA 6P
Max Operating Temperature (°C)
70
Min Operating Temperature (°C)
-20
Max Op. Relative Humidity Non-Condensing (%)
100
Warm-up Time (minutes)
15
Minimum Response Time (ms)
96
Analog Linearity (mm)
+/- 0.5% of full-scale span
Barrel Diameter (mm)
30
Minimum Window Size (mm)
10
Remote Teach and Laser Control Input Impedence
55 kΩ
Discrete Output Hysteresis (mm)
2.5
Ultrasonic Frequency (kHz)
128
Max Off-state Leakage Current (µA)
10
Power/Current Consumption (exclusive of load)
90 mA
Supply Protection Circuitry
Protected against reverse polarity and transient overvoltages
Feature: Remote Teach
Yes
Feature: Clear Object Detection
Yes
Feature: Timing (Hold/Delay)
No
Feature: Chemical Resistant
No
Application: Ultrasonic
Yes
Common Ethernet Protocol
No
IO Link
No
PROFINET
No
RS-232
No
RS-422
No
RS-485
No
SSI
No
Wireless
No
1-wire Serial Interface
No
Profibus
No

The following products are included with your order

CAD Files

Date
Type
Size
T30U NB/PB CABLE/PIGTAIL
25 May 2011
DXF
600K
T30U NB/PB CABLE/PIGTAIL
25 May 2011
IGS
2.3MB
T30U NB/PB CABLE/PIGTAIL
25 May 2011
PDF
85K
T30U NB/PB CABLE/PIGTAIL
25 May 2011
STP
1.6MB

Technical Literature

Date
Type
Size
U-GAGE T30U Ultrasonic Series,  Analog
10 May 2019
DATA SHEET
414K

Certification

Date
Type
Size
DoC for T30U
17 Oct 2018
CERTIFICATION
6MB
T30UINB
T30UINB
Item Detail: T30U Series 2 m Range Pump Control Ultrasonic Sensor

Certifications