Relè di sicurezza di muting

Serie MMD

MMD DIM
  • Suspends safeguarding during hazard-free times in the machine’s cycle
  • Allows material to move into or from the process, without tripping the primary safeguard
  • Monitors two or four hard-relay contact or OSSD output safety devices
  • Available in models for Type 2 and Type 4 applications
  • Offers 24V dc supply voltage with either two solid-state OSSD or 2 normally open (NO) safety outputs
  • Includes one non-safety auxiliary output
  • Offers two reset options: Automatic and Monitored Manual
  • Uses diverse redundancy and self-checking, for reliability
  • Features models for DIN-rail mounting or IP65-rated housing for flat mounting
  • Mounts outside a control panel, near the muted safeguard, or inside the control panel
  • Installs easily
  • Connects to supplemental safeguarding devices or E-stops

 

  • Sospende la protezione durante le fasi senza rischio del ciclo macchina
  • Consente il transito di materiale da e verso il processo, senza causare l'intervento della sicurezza primaria
  • Esegue il monitoraggio di due o quattro dispositivi di sicurezza con contatti meccanici a relè o con uscite OSSD
  • Disponibile nelle versioni per applicazioni Tipo 2 e Tipo 4
  • Realizzato con tensione di alimentazione 24 Vcc, con due OSSD a stato solido o 2 uscite di sicurezza normalmente aperte (NA)
  • Comprende un'uscita ausiliaria non di sicurezza
  • Dispone di due opzioni di reset: automatico e manuale monitorato
  • Utilizza una tecnologia a ridondanza diversificata e funzionalità di autodiagnostica per la massima affidabilità
  • Disponibile nella versione per montaggio su barra DIN o con custodia con grado di protezione IP65 per il montaggio su superficie piana
  • Installabile all'esterno del quadro di controllo, vicino a un dispositivo di protezione inibito, o all'interno del quadro di controllo
  • Facile installazione
  • Collegabile a dispositivi di protezione supplementari o a pulsanti di arresto di emergenza

       

Letteratura tecnica

Data
Tipo
Dimensione
MMD-TA- 11B and MMD-TA-12B Muting Module
26 Jun 2019
Manuale del prodotto
924K
MM2-TA-12B Muting Module
MM2-TA-12B Muting Module
3 Nov 2005
Manuale del prodotto
1.9MB
MM-TA-12B Muting Module
MM-TA-12B Muting Module
14 Nov 2003
Manuale del prodotto
958K
Data
Tipo
Dimensione
MMD-TA- 11B and MMD-TA-12B Muting Module - French
11/21/07
Manuale del prodotto
3.8MB
MM-TA-12B Muting Module Manual - French
11/16/06
Manuale del prodotto
1.9MB
MM-TA-12B Muting Module (Six Monthly Checkout) - French
05/02/06
Manuale del prodotto
172K
MM-TA-12B Muting Module Daily Checkout - French
05/02/06
Manuale del prodotto
76K
Data
Tipo
Dimensione
MMD-TA- 11B and MMD-TA-12B Muting Module - German
11/21/07
Manuale del prodotto
3.8MB
MM-TA-12B Muting Modul Manual - German
11/16/06
Manuale del prodotto
2.2MB
MM-TA-12B Six Monthly Checkout - German
05/02/06
Manuale del prodotto
171K
MM-TA-12B Daily Checkout - German
05/02/06
Manuale del prodotto
156K
Data
Tipo
Dimensione
MM-TA-12B Muting Modul Manual - Italian
11/16/06
Manuale del prodotto
4.5MB
MM-TA-12B Six Monthly Checkout - Italian
05/02/06
Manuale del prodotto
166K
MM-TA-12B Daily Checkout - Italian
03/10/06
Manuale del prodotto
80K
Data
Tipo
Dimensione
MM-TA-12B Muting Module - Japanese
04/28/11
Manuale del prodotto
1.6MB

Brochure e Cataloghi

Data
Tipo
Dimensione
Safety Overview Flyer
Safety Overview Flyer
15 Feb 2023
Brochure prodotto
2.5MB
(Part D) 2006-07 Safety Catalog (Pg 105-134) - Safety Modules
4 Apr 2006
Catalogo
1.9MB
Data
Tipo
Dimensione
F142 Safety Solutions Brochure
01/06/21
Brochure prodotto
16.4MB

Selezione prodotto

Caricamento in corso...

Restringi i risultati

Cancella tutti i filtri

Configurazione output

  • (1)
  • (1)
Visualizza tutto Visualizza meno
Filtri selezionati
  1. MMD-TA-11B

    logo with r symbol

    Safety Relay Muting Module
    Supply Voltage: 24 V ac/dc
    Muteable Safety Input: 1 Dual Channel
    Non-Muteable Safety Input: 1 Dual Channel
    Safety Output: 2 NO, 6 A; Aux Output: 1 NC, 0.25 A
    Terminal Block: Removable; Width: 67.5 mm
    Self-Checking Circuitry, Auto/Manual Reset, EDM, Muting

  2. MMD-TA-12B

    logo with r symbol

    Safety Relay Muting Module
    Supply Voltage: 24 V ac/dc
    Muteable Safety Input: 1 Dual Channel
    Non-Muteable Safety Input: 1 Dual Channel
    Safety Output: 2 PNP, 500 mA; Aux Output: 1 PNP, 250 mA (follows OSSDs)
    Terminal Block: Removable; Width: 67.5 mm
    Self-Checking Circuitry, Auto/Manual Reset, EDM, Muting

Aggiungi alla mia libreria